Documentation for Face PSIM 1.0.1.

Previous page Face recognition server settings panel  Appendix 2. Debug window Next page

The Face recognition and search object settings panel includes the following interface elements.

The description of the Face recognition and search interface object settings is given in the table.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

The Position group

1

X

Enter the value into the field

Sets a coordinate in the horizontal X-axis for the upper left corner of the Face recognition and search window on the screen

% of the computer screen width

-

From 0 to M*100, where Mnumber of installed video surveillance monitors

2

Y

Enter the value into the field

Sets a coordinate in the vertical Y-axis for the upper left corner of the Face recognition and search window on the screen

% of the computer screen height

-

From 0 to M*100, where Mnumber of installed video surveillance monitors

3

W

Enter the value into the field

Sets the width of the Face recognition and search window

% of the computer screen width

-

From 0 to M*100, where Mthe number of installed video surveillance monitors

4

H

Enter the value into the field

Sets the height of the Face recognition and search window

% of the computer screen height

-

From 0 to M*100, where M—number of installed video surveillance monitors

5XClick the buttonDisplays the text window for visual setting of the coordinates and sizes of the Face recognition and search window---
6Allow movingSet the checkboxEnables moving the Face recognition and search windowBoolean type

Clear


Set—moving is enabled 

Clear—moving is disabled

7MonitorSelect the value from the listSets the physical monitor for displaying the Face recognition and search windowSequence of numbers1From 1 to 16

The Recognizers tab.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Available face recognizersAutomaticDisplays the list of the available Face recognition server objects---
2The >, <, >>, << buttonsClick the buttonSelect the Face recognition server objects for operation with the Face recognition and search object---
3Selected face recognizers AutomaticDisplays list of Face recognition server objects selected for operation with the Face recognition and search object---
4Minimum similarity for identificationEnter the value into the fieldSets the value of minimum similarity of the captured face image and the reference face image%80From 0 to 100

The Color highlighting tab.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1Divide into departments with color marking

Select a Department object and set a color from the Windows palette

Sets the highlight color of the recognized faces that belong to the selected departments

Names of the Department objects registered in the system and color from the Windows palette 

--
2Red zoneEnter the value into the fieldSets the lower value of the red zone. If the face recognition match percentage is equal to or higher than the specified value, then the information under the recognized face will be highlighted in red%80From 0 to 100
3Yellow zoneEnter the value into the fieldSets the lower value of the yellow zone. If the face recognition match percentage is equal to or higher than the specified value, but does not exceed the lower limit of the red zone, then the information under the recognized face will be highlighted in yellow%50From 0 to 100
4Alarm window title bar colorSelect a color from the Windows paletteSets the color of the alarm windowThe colors from the Windows paletteRed-
5Redefine titleSet the checkbox

Enables specifying an arbitrary title name

Boolean typeClear

Set—specifying an arbitrary title name is enabled

Clear—specifying an arbitrary title name is disabled

6

Text field for specifying an arbitrary title

Enter the value into the fieldSets the specified arbitrary title of the alarm windowString--

The Permissions tab.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1Allow face database editingSet the checkboxEnables the possibility to edit the reference face databaseBoolean typeSet

Set—face database editing is enabled.

Clear—face database editing is disabled

2Allow creating departmentsSet the checkboxEnables/disables the automatic department creation in Axxon PSIM with the specified name for cases when a reference face is added to the reference face database, and a non-existent department is specifiedBoolean typeSet

Set—the automatic department creation is enabled.

Clear—the automatic department creation is disabled

3Create users in Axxon PSIMSelect the value from the list

Sets the options for creating users in Axxon PSIM when the face is added to the reference face database

Options for creating users in Axxon PSIMAllow selection

Allow selection—when the face is added to the reference face database, the Create a user in the Axxon PSIM database checkbox is available for the operator (see Adding images to the reference face database).

Create—the Create a user in the Axxon PSIM database checkbox is absent in the operator's interface, and Axxon PSIM users are created automatically when the face is added to the reference face database.

Do not create—the Create a user in the Axxon PSIM database checkbox is absent in the operator's interface, and Axxon PSIM users are not created when the face is added to the reference face database

4Monitors to controlSelect the value from the listSets the Monitor interface object for video archive controlNames of the Monitor objects registered in the system-Depends on the number of the Monitor objects in the system
5UrlEnter the value into the fieldSets the permanent part of the link for the called web-page by the result of the face search---
6Columns auto widthSet the checkboxDisables the automatic columns resizing in the Face recognition and search window in proportion to the interface window sizeBoolean typeSet

Set—the automatic columns resizing is enabled.

Clear—the automatic columns resizing is disabled

7Additional settingsClick the buttonDisplays the Advanced settings window for selecting the advanced face characteristics that should be recognized---

The Map settings tab.

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
1Control mapSelect the value from the listSets the Map interface object to display on it the cameras that captured a face, as well as a movement track of a person and additional information about the track Names of the Map objects registered in the system-Depends on the number of the Map objects in the system
2Additional information to display in the title near the arrows on the map when tracking the movement of a person if their face was recognized

Show name in trackSet the checkboxAdds/deletes the name of a personBoolean typeClear

Set—the name of a person is displayed in the title

Clear—the name of a person isn't displayed in the title


Show departmentSet the checkboxAdds/deletes the department to which the person belongsBoolean typeClear 

Set—the department to which the person belongs is displayed in the title

Clear—the department to which the person belongs isn't displayed in the title


Show similaritySet the checkboxAdds/deletes the percentage of similarity between the recognized face and the reference faceBoolean typeClear

Set—the percentage of similarity between the recognized face and the reference face is displayed in the title

Clear—the percentage of similarity between the recognized face and the reference face isn't displayed in the title


Show start timeSet the checkboxAdds/deletes the time of a person's appearance in the FOV of a cameraBoolean typeClear

Set—the time of person's appearance in the FOV of a camera is displayed in the title

Clear—the start time of a person’s movement in the FOV of a camera isn't displayed in the title


Show end timeSet the checkboxAdds/deletes the time of a person's disappearance in the FOV of a cameraBoolean typeClear

Set—the time of person's disappearance in the FOV of a camera is displayed in the title

Clear—the time of person's disappearance in the FOV of a camera isn't displayed in the title


Display repeated events from same cameraSet the checkboxDisables filtering for events where the same person appears several times in a row in the FOV of the same cameraBoolean typeClear

Set—filtering for events where the same person appears several times in a row in the FOV of the same camera is disabled

Clear—filtering for events where the same person appears several times in a row in the FOV of the same camera is enabled

3Title positionSelect the value from the listDetermines the position of the title near the arrowOptions for title position-

At arrow beginning—the title is displayed at arrow beginning

At arrow endthe title is displayed at arrow end

At arrow middlethe title is displayed at arrow middle

4FontClick the buttonDisplays the Font window in which the font parameters of the title are configured---

The Advanced settings tab.

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
1File names separatorsEnter the value into the fieldSets the characters that will be used as a separator when adding faces to the database

Cyrillic letters, Latin letters, numbers, symbols, additional characters, white space

_.

(underscore, period and a white space)

-
2Simple modeSet the checkboxEnables/disables the simple mode of captured and recognized faces monitoringBoolean typeClear

Set—the simple mode is enabled

Clear—the simple mode is disabled