Go to documentation repository
Documentation for Intellect 4.10.4. Documentation for other versions of Intellect is available too.
New features and improvements
- The archive on the failover server is now synced with the archive on the main server after recovery. This uses the Video Backup module.
- File system revamped:
- Optimized loop-based recording and data deletion in multi-disk configurations
- Accelerated reading video archive indexes
- Increased stability and performance.
- Videogate supports multistreaming (streams all video feeds from a camera).
- Videogate allows constant recording for only the cameras that are streamed to clients.
- Object classification (human, vehicle, or group of people) is available for live video detection tools and recorded video searches using the VMDA system.
- The tracker can trigger an alert when it detects a specific number of objects in the frame.
- Added the ability to create multiple masks in the VMDA tracker.
- VMDA detection tools don't require constant recording.
- GreenStream switches between streams with digital zooming.
- Moving objects are tracked on the map for the Strelets-Integral ISS.
- The operator's screen has a new Maintain camera aspect ratio setting to correctly display images from cameras with different aspect ratios.
- A new utility moves logging to a separate database keeping web reports efficient.
- The Bookmarks window now has search and filters.
- In the map editor, breakpoints can be added to a line using CTRL + right-click.
- The map editor displays object states in turn, rather than simultaneously (if there are multiple states).
- Export is available for dewarped video from cameras with a fisheye or rotated image.
- The Operator Log allows delayed alerts and hiding/showing the alert buttons.
- Improved control of playback speed and toggling playback between forward and reverse using the arrow buttons.
- Keyboard shortcuts can be assigned to macros.
- Multi-selection of archives with Ctrl or Shift when setting up protection of video recordings.
- Color can be configured for polygons and circles on the map using ddi utility.
- The title search now has an option to search for a substring.
- The Event Log shows the card number for all events associated with cards.
- The Map | Fit to Window command can be used in macros and scripts. It shows the entire map in the window.
- The name of a monitor can be displayed on the panel.
- Added the MaximizeCameraOnDblClk and MinimizeCameraOnDblClk registry keys to control the switch to single camera window view and back by double-clicking the camera in the Monitor.
- Scripts have a timer function that works without creating a timer in the object tree.
- Added the MonitorPlaybackControlByMouseWheel registry key for using the mouse wheel to control the playback speed.
- A new option in the General settings opens the documentation when you press F1.
- The detection tool can show a box that marks where an object appeared or disappeared.
- Integration with Manitou monitoring software.
- The Operator Log has new fields that show the Operator (who handled the event) and the Response (the decision that was made).
- Added Korean localization.
- Many small improvements in the Event Log.
- Added the ConnectOnlyByClient registry key to disable the transfer of video from the server to Videogate if the client does not request video.
- Added the savemode registry key, which allows you not to exit the archive mode when changing the layout.
- Added the BookmarkMaxLen registry key, which allows you to limit the maximum archive history for a bookmark in the Monitor.
- Added the ability to filter objects on the computer in the Event Log filter.
- Added a script for displaying a minimap and an event that is generated when it is closed.
Bug fixes
- Corrected audio recording so the audio is recorded at the frequency set in microphone settings.
- Fixed how archives are displayed in the calendar — users with restricted access can't see archive information.
- On the archive calendar, days that have an archive available are always shown in bold now.
- A problem has been fixed where the microphones of certain IP cameras were not shown in the sound card settings.
- Corrected a problem with the title search not working in the Monitoring and ATM modules.
- Fixed a problem with remote workstations accessing archives from cameras behind a Videogate.
- Fixed an error downloading the ddi file when starting Intellect if there are multiple ddi files of the same type nearby.
- Fixed an error that caused video playback to stop when it was slowed down.
- Fixed an error with changing the sensor/relay performer when added through IPWizard.
- Resolved an issue with the web server not receiving video from Videogate.
- Corrected event sorting in the Event Log.
- Monitor no longer freezes up on the remote monitoring workstation when displayed through Videogate.
- Resolved an access issue so users who don't have camera management rights can no longer control the camera.
- The Record button in the remote workstation sometimes stopped working if the camera was streamed through Videogate. This has been fixed.
- The camera always exits the archive viewing mode when changing layouts now (if this is configured).
- The web server starts up quickly now.
- The Hide Object IDs option works correctly now to hide object IDs on the map.
- Corrected the problem with audio.run crashing when the microphone was physically connected to the camera.
- Resolved an issue with crashes when deleting map layer connections.
- Fixed a problem that caused crashes when configuring disks in Videogate.
- The Failover service now always transfers the objects after the connection is re-established.
- Fixed an issue with audio distortions in archives exported in the background.
- Fixed an error that caused crashes during system configuration on certain OS locales.
- The link to a map layer where an alert was triggered always blinks now.
- Archive navigation with the arrow buttons works correctly now.
- Fixed an error that caused crashes when many trackers were created.
- Synced the time zones for the titles and descriptions of exported videos.
- Fixed a problem in which brief sensor triggering were ignored.
- Fixed a problem with the macro not working to remove cameras from the monitor.
- Resolved an issue with incomplete syncing of archives from Remote Storage.
- Fixed crashes caused by setting the wrong window size in the Event Log.
- The Camera Time option now works correctly to show the camera's time in the monitor.
- Fixed the installation of WS6 drivers on Windows 7 (32 bit).
- Fixed a problem with not showing archives from Remote Storage.
- Corrected the problem with increased memory consumption on the web server.
- Fixed jerkiness in live/archived video.
- Resolved a problem with artifacts appearing in the archive.
- Fixed an error when the playback button disappeared during VMDA search.
- The macro works correctly now for exporting archives.
- Archives with a low frequency of reference frames export correctly now.
- Video playback now works correctly from the title search window.
- Resolved an issue in which the board code was not returned when requested through the ATM module.
- Older events in the Event Log are deleted correctly now.
- Fixed an error that reduced the frame rate for live video on other cameras when fast forwarding a certain archive.
- Now the next DNS server in the list is reconnected to even if the remote workstation was installed and configured under a non-administrator OS account.
- User authorization with supervisor confirmation is now performed correctly on the remote workstation.
- When a server was disconnected, it sometimes took a long time for the Failover server to receive the lost connection event. This has been fixed.
- Corrected the problem with controlling the font size in titles through the FontCamNameHeight and FontCamTimeHeight registry keys.
- Fixed the issue with deleting the indexes of the STATES table when syncing.
- Fixed an issue that could cause crashes when objects were deleted from the map.
- Resolved a problem with the kernel accumulating queues when the web server is running.
- A problem with the archive audio not starting after a pause has been fixed.
- Fixed an error that caused the first few seconds of a recording to be missing in an archive exported to AVI.
- Prerecording audio now works correctly.
- Fast forwarding a video through Videogate was slower than without Videogate. This has been fixed.
- Reduced CPU load when requesting a stream from the web server.
- Improved tracking performance for certain platforms.
- Audio recording now works correctly in the Audio Player.
- Polish characters are now displayed correctly in mobile clients.
- The Video Backup now works correctly if the main archive has a damaged file.
- CTRL + C and CTRL + V now work to copy configuration objects after the user logs in.
- Corrected the list of cameras in the Synchronization tab for the Computer object in distributed systems.
- Fixed a problem with controlling PTZ cameras on WaveServer 1554.
- Fixed an issue in which the VMDA detection tool generated alerts for a camera even if this option is turned off.
- Fixed a problem that caused crashes when using multistreaming on the Hikvision DS-2CD4A26FWD-IZHS/P camera.
- The Event Log window no longer closes with ALT + F4.
- Fixed an error that caused crashes when exiting the archive during export.
- Fixed an error that caused crashes when exporting an archive with 4K resolution.
- Disabled objects are no longer displayed on the map.
- Fixed an error that prevented the communications subsystem reports being generated.
- After Intellect restarted, the Event Log stopped displaying videos of old events. This has been fixed.
- Line objects are now displayed correctly on the map.
- Corrected how long camera names are displayed for small monitors.
- The kernel has been optimized for many large events.
- Corrected the problem where the link to the map layer might have the wrong color.
- Fixed the issue that made switching between screens too slow.
- Titles no longer disappear when increasing the size of the camera window in the monitor.
- The password is hidden now in the Video Input Device Setup window.
- Resolved an issue with events not loading in the Event Log when the Load Log option was enabled.
- Corrected the problem where a PTZ camera might pivot when the speaker icon was clicked on the monitor.
- Audio from archives in a distributed configuration is played back correctly now.
- Archive playback now switches smoothly from fast forward to normal speed.
- Fixed the video.run module crashing if the system disk ran out of space.
- Fixed the issue that returned an incorrect state of sensors through the HTTP API.
- Fixed the issue with video export to .exe format using AviExport utility.
- Fixed the issue with video export with sound using AviExport utility.
- Fixed an issue that caused Intellect to stop working with the video capture cards in a few days.
- Fixed a bug that prevented protected records from playing in mobile clients.
- Fixed Intellect bugs with the “Keep under” and “Keep over” settings.
- Fixed the installer CamMonitorInstaller.exe not installing the necessary libraries.
- Fixed the loss of sound from Vivotek cameras connected via Vivotek General Device.
- Fixed streams switching in the Monitor window when “Automatic selection of streams to display” is disabled.
- Fixed an issue with exporting a live video frame with the resolution of the camera window, rather than the resolution of the video.
- Fixed the HTML interface error that caused returning to the home page when another user logged in.
- Fixed the error occurred when objects were copied together with child objects.
- Fixed the bug behind the crashing of StreamingServer.run when playing back recorded footage via RTSP.
- Fixed the issue with facial recognition tools on multistreaming cameras.
- Improved stability of scripts.
Resources