Documentation for ACFA PSIM 1.3.

Previous page General information about working with the BioSmart integration module  Managing the BioSmart terminals and controllers Next page

To get the BioSmart biometric parameters for the Access Manager module:

  • from the BioSmart parent object, a biometric face template from the Access Manager photo or other image file is added that is suitable for the BioSmart Quasar terminal;
  • from the DCR-PV control reader, a biometric template of palm veins is added that is suitable for the PV-WTC terminal and the UniPass controller;
  • from the Biosmart PV-WTC terminal, a biometric template of palm veins is added that is suitable for the PV-WTC terminal and the UniPass controller;
  • from the PalmJet reader, working with Unipass Pro, a biometric template of palm veins is added that is suitable for the PalmJet reader;
  • from the AirPalm/PalmJet control reader (from AirPalm via USB or PalmJet via Ethernet, if PalmJet is connected directly to the local network and not to Unipass Pro) a biometric template of palm veins is added that is suitable for the AirPalm/PalmJet reader;

  • from the BioSmart Quasar terminal, a biometric face template is added;
  • from the Biosmart 4 controller, a biometric fingerprint template is added that is suitable for the Biosmart 4 controller and the Biosmart Mini reader (under the control of the Prox-E controller);
  • from the FS-80 control reader, a biometric fingerprint template is added that is suitable for the Biosmart 4 controller and the Biosmart Mini reader (under the control of the Prox-E controller).

Before you start, you need to configure the interaction of the reader connected to the BioSmart controller, or the interaction of the BioSmart terminal with the Access Manager module (see Configuring interaction of the BioSmart integration module with the Access Manager module and Time and Attendance subsystem).

Below you can see an example of adding biometric parameters using the Biosmart PV-WTC terminal and DCR-PV USB control reader.

Adding biometric parameters using the Biosmart PV-WTC terminal

To add biometric parameters using the Biosmart PV-WTC terminal, do the following:

  1. Go to adding biometric data in the Access Manager window (see Adding biometric parameters).
  2. Select the corresponding extension: (Biosmart Biometrics) PV-WTC. The Operations on biometrics dialog window will open.
  3. Click the Add templates button.

    Note

    The Delete all the templates button removes all palm templates that you added earlier.
  4. The Reading biometric data dialog window appears. Follow the instructions on the terminal screen.
  5. If the palm template is successfully received, a message will be displayed.
  6. Click the Ready button to save the template.
  7. Similarly, you can add as many templates as the terminal configuration allows (see Configuring the BioSmart PV-WTC terminal). The Operations on biometrics window displays the number of saved templates.

Adding biometric parameters using the DCR-PV USB control reader

To add biometric parameters using the DCR-PV USB control reader, do the following:

  1. Go to adding biometric data in the Access Manager window (see Adding biometric parameters).
  2. Select the corresponding extension: (Biosmart Biometrics) DCR-PV control reader. The Operations on biometrics dialog window will open.
  3. Click the Add templates button.

    Note

    The Delete all the templates button removes all palm templates that you added earlier.
  4. The Reading biometric data dialog window will open. Put your palm to the reader.
  5. When the biometric data is received, put the same palm to the reader again.
  6. If the operation is successful, the message Biometric data is successfully received will appear.
  7. Click the Ready buttton to save the template.