To configure the MicroTrack II control segment go to the settings panel of the MicroTrack II Segment object. This object is created on the basis of the MicroTrack II object on the Hardware tab of the System settings dialog window.

To configure the MicroTrack II control segment, do the following:

  1. Go to the MicroTrack II Segment object’s settings panel.
  2. In the Beginning field (1) using the up-down buttons enter the number of subcell corresponding to the key point in which the control segment started.
  3. In the End field (2) using the up-down buttons enter the number of subcell corresponding to the key point in which the control segment finished.

    Note.

    The range of values of Beginning and End fields is from 0 to 215. It is not recommended for the control segments to overlap one another.

    Attention!

    Value in the End field should not exceed the value in the Beginning field.
  4. In the Timeout field (3) set the interval, after which the alarm will be activated.
  5. In the Control AIM field (4) select alarm input of the AIM II controller, which the trigger the alarm at a given interval.
  6. In the Alarm fix cause table (5) specify up to 10 alarm descriptions, one of which can be selected by an operator when processing the alarm of a MicroTrack II segment on the map (see Managing MicroTrack II and MicroPoint II control segments).
  7. Click Apply button (6).

Configuring the MicroTrack II control segment is completed.