To configure a V2000 controller's doors, use the setup panel of the relevant Door (V2000) object: go to the Settings dialog box, click the Hardware tab, select the relevant parent VertX V2000 NC/RI object, and browse its object subtree.

To configure the doors:

  1. Go to the Door (V2000) object's setup panel.
  2. If the REX switch is enabled, select the REX Enabled checkbox (1).
  3. Configure the REX switch limits (see Section Configuring EEPROM ) (2).
  4. In the REX debounce time, msec field, enter the time period (in milliseconds) to be used for fixing (debouncing) the bouncing REX switch signal(3).
  5. If the door switch is enabled, select the Door switch enabled checkbox(4).
  6. Configure the door switch limits (see Section Configuring EEPROM ) (5).
  7. In the Door switch debounce time, msec field, enter the time period (in milliseconds) to be used for fixing (debouncing) the bouncing door switch signal (6).
  8. In the Position field, select the position of the door (7). 
  9. In the Door priority level field, use the up and down buttons to set the door priority level (8).
  10. In the Norm. grant access time, msec field, enter a time period (in milliseconds). This is the time period during which the door allows access, in normal access mode (9).
  11. In the Ext. grant access time, msec field, enter a time period (in milliseconds). This is the time period during which the door allows access, in extended access mode (10).
  12. To use the door in extended access mode, select the Use extended access mode checkbox (11).
  13. In the Min open time, msec field, enter the minimum time period allocated for opening the door (12).
  14. In the Door held time, msec field, enter a time period (in milliseconds). This the time during which the door's lock is kept open after entry (13).
  15. In the REX open time, msec field, enter the time period (in milliseconds) allocated for opening the door with the REX switch (14).
  16. Select the required radio button from the REXUD option radio button group: REX unlocks door - only the REX switch can unlock the door; REX permits door to be unlocked manually - allows the door to be unlocked manually as well (15).
  17. Click Apply to save the changes (16).
  18. Configure the door strike relay:
    1. Under the Door (V2000) object, find the Door strike relay object. Go to the setup panel of the Door strike relay object.
    2. In the Minimum open time, msec field, enter a time period (in milliseconds). This is the minimum time period during which the door strike relay is open (1).
    3. Click Apply to save the changes (2).

The doors are now configured.