Go to documentation repository
Documentation for ACFA PSIM 1.3.
The Rakinda device is configured as follows:
- Go to the settings panel of the Rakinda device object that is created automatically on the basis of the Rakinda object (see Configuring the connection of the Rakinda parent object).
- In order to send the QR code generated by the Rakinda device to user’s email, specify the settings of the SMTP server that depend on the mail server that you use.
- In the SMTP server (1) and SMTP port (2) fields, specify the address of the mail server and port number.
- In the User name (3) and Password (4) fields, specify the user’s login and password.
- In the Mailing address field (5), enter the user’s email address.
- From the QR interpretation drop-down list (6), select the field that the device expects to see in the QR code. In this integration—only User Id.
- In the Device key field (7), enter the device key that is specified in the Rakinda device passport.
- Set the Enable Qr-code analysis checkbox (8). If the checkbox is set, when the device gets two-dimensional code, it sends it directly to the server to make a decision, or determines two-dimensional code itself.
- Click the Get time button (9) to request the time from the Rakinda device.
- Click the Set time button (10) to record time on the Rakinda device.
- From the Entrance (11) and Exit (12) drop-down lists, select the user’s entrance and exit regions, respectively.
- Click the Apply button (13) to save the changes.
The Rakinda device configuration is now complete.
Overview