Documentation for ACFA PSIM 1.3.

Previous page Preconfiguring the software of the BioStar 2 manufacturer  Used software of the BioStar 2 manufacturer Next page

To work with the BioStar 2 integration module, you must install and configure the AxACFA feature. For more details, see Connecting and configuring the AxACFA feature.

To configure the BioStar 2 parent object, do the following:

  1. Create the BioStar 2 parent object on the basis of the Axacfa object on the Hardware tab of the System settings dialog window.

  2. In the API Host field, specify the IP address to connect to the BioStar 2 Server.

  3. In the API User Login field, specify the user identifier to connect to the BioStar 2 Server.

  4. In the API User Password field, specify the user password to connect to the BioStar 2 Server.

  5. In the Status update period (msec) field, specify in milliseconds the time period of hardware status update.

  6. Click the Apply button to save the connection settings.
  7. To download the configuration and automatically build the hardware tree, click the Download configuration button. A hardware tree will be built: