The AIO alarm panel's relay is configured on the settings panel of the corresponding object. An Apollo Relay object is created based on an AIO Alarm Panel object.
The relay is configured as follows:
- Go to the Apollo Relay object's settings panel.
- From the Relay number dropdown list select the relay's index number (1).
From the Operating mode dropdown list select the relay's operating mode (2).
Relay operating mode
Description
Disabled
The relay is open
Enabled
The relay is closed
Locally linked to inputs
The state of the relay depends on the state of the alarm inputs and inputs
- Set the Impulse duration:
- From the Unit dropdown list select the units of measurement for the impulse duration (4).
- In the Impulse duration field, specify the duration (in terms of the selected units of measurement) of the impulse (3).
- To make it possible to reset the impulse when changing the operating mode to Disabled, set the Use Disabled for impulse reset option (5).
- Set the Link to connection input option if the relay should react to the state of the Connection input (6).
- Set the Link to any input failure option if the relay should react to a fault on any of the inputs (7).
- Set the Link to housing tamper input option if the relay should react to the state of the alarm panel's cabinet (8).
- Set the Link to power failure input option if the relay should react to the state of the alarm panel's power supply (9).
Configure the interaction between the relay and the alarm inputs (10). In the Action column, select the alarm input states in which the relay will close.
State
Description
None
The relay will be open regardless of the alarm input state
Alarm and tamper sensor
The relay will be actuated in the following cases:
- An alarm message is received from the alarm input.
- A message is received from the tamper sensor.
Alarm/mask and tamper sensor
The relay will be actuated in the following cases:
- An alarm message is received from the alarm input.
- An alarm message is received from the alarm input when it is disarmed.
- A message is received from the tamper sensor.
Alarm/mask, tamper sensor and failure
The relay will be actuated in the following cases:
- An alarm message is received from the alarm input.
- An alarm message is received from the alarm input when it is disarmed.
- A message is received from the input's tamper sensor.
- A fault message is received.
- To save any changes made, click the Apply button (11).
This completes the configuration of the AIO alarm panel's relay.