Go to documentation repository
Previous page Next page
At least 2 APB areas are to be configured in the system corresponding to entrance and exit regions of a reader. The first APB zone is intended to control people count, and limits are set in it for number of users in region. The second APB area does not necessarily have limitations on user number but entrance to this zone reduces number of users in the first zone according to readers configuration.
Create 2 regions in ACFA Intellect: Inside and Outside. These regions are set as entrance or exit areas for readers 1 and 2:
The APB Zone 1 is associated with the Inside region and has limited user count of 5. The APB Zone 2 is associated with the Outside region and has no limitations on user count.
When 5 persons has entered the APB Area 1 through Reader 1, the area is locked and it is impossible ti enter in it. But if 1 person leaves APB Area 1 through Reader 2 (i.e. enters APB Area 2), then APB Area 1 unlocks as so as the number of persons in it becomes 4.
So, not more than 5 persons in zone is maintained.
Note.