Previous page Next page


The figure shows the Access Manager interface object settings panel.

 

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

The Position group

1

Fix position checkbox

Settings checkbox

Is used if it's required to specify coordinates of the Access Manager window and forbid its moving

Boolean type

No

Yes – position of the Access Manager window is fixed.

No – position of the Access Manager window can be changed.

2

Monitor drop-down list

Selecting the value in the list

Sets the number of monitor on which the Access Manager window will be displayed

List of accessible computer monitors

Monitor 1

Depends on the number of connected computer monitors

3




X:

Setting the value in the field

Sets X coordinate of the upper left corner of the Access Manager window

%  of screen width

0

From 0 to M*100, where M is a number of computer monitors

Y:

Setting the value in the field

Sets Y coordinate of the upper left corner of the Access Manager window

% of screen height

0

From 0 to M*100, where M is a number of computer monitors

W:

Setting the value in the field

Sets the Access Manager window width

%  of screen width

0

From 0 to M*100, where M is a number of computer monitors

H:

Setting the value in the field

Sets the Access Manager window height

% of screen height

0

From 0 to M*100, where M is a number of computer monitors

Out of groups
4Create users with APB checkboxCheckbox

Sets the default setting for the user antipassback parameter 

Boolean typeNo

Yes - by default, the users are created with enabled antipassback

No - by default, the users are created with disabled antipassback

5

New departments are visible in root checkbox

Checkbox

Sets availability of new created departments in the Access Manager hierarchy root

Boolean type

Yes

Yes – new departments are available in the Access Manager hierarchy root

No – new departments are not available in the Access Manager hierarchy root

6Tab navigation buttonsClick the buttonButtons switch the active tab---

Departments tab

 

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

Departments tree

Settings checkbox

Sets available departments in the Access Manager window

Boolean type

Set of boolean variables

Department will be available in the Access Manager window if  checkbox is set close to it

Access levels tab

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

Mode drop-down listSelecting the value in the listSets the access restriction mode for access levels in the Access Manager interface object-Prohibition

Prohibition - restrict the access

Permission - allow the access

2Access levels treeCheckboxSpecifies the access levels, the access to which should be configuredBoolean typeA set of boolean variablesIf the checkbox is set for the access level, the selected access restriction mode will be applied to it in the Access Manager interface object
3Actions buttonSelecting the value in the listOpens a list of actions for managing the access levels tree--

Minimize - minimizes all access levels in the tree

Expand - expands all access levels in the tree

Select all - sets the checkboxes for all access levels

Remove all - removes checkboxes for all access levels

Search - opens the Access level or folder search window for access level or folder searching by the name or identifier

Time zones tab

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

Mode drop-down listSelecting the value in the listSets the access restriction mode for time zones in the Access Manager interface object-Prohibition

Prohibition - restrict the access

Permission - allow the access

2Time zones treeCheckboxSpecifies the time zones, the access to which should be configuredBoolean typeA set of boolean variablesIf the checkbox is set for the time zone, the selected access restriction mode will be applied to it in the Access Manager interface object
3Actions buttonSelecting the value in the listOpens a list of actions for managing the time zones tree--

Minimize - minimizes all time zones in the tree

Expand - expands all time zones in the tree

Select all - sets the checkboxes for all time zones

Remove all - removes checkboxes for all time zones

Search - opens the Time zone or folder search window for time zone or folder searching by the name or identifier

Right tab

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

Object management rights group

1

Create checkbox

Checkbox

Sets possibility to create the corresponding object in the Access Manager window

Boolean type

Yes

Yes – creating the corresponding object from the Access Manager window is allowed.

No – creating the corresponding object from the Access Manager window is forbidden.

Delete checkbox

Checkbox

Sets possibility to delete the corresponding object in the Access Manager window

Boolean type

Yes

Yes – deleting the corresponding object from the Access Manager window is allowed.

No – deleting the corresponding object from the Access Manager window is forbidden.

Edit checkbox

Checkbox

Sets possibility to edit the corresponding object in the Access Manager window

Boolean type

Yes

Yes – editing the corresponding object from the Access Manager window is allowed.

No – editing the corresponding object from the Access Manager window is forbidden.

2Check all button




3Uncheck all button




Forbid to delete group
4Non-empty departments checkboxSettings checkboxForbids to delete departments if there are users in themBoolean typeNo

Yes – non-empty departments cannot be deleted.

No – non-empty departments can be deleted.

5Assigned Access Levels checkboxSettings checkboxForbids to delete access levels if they are assigned to user(s)Boolean typeNo

Yes – assigned access levels cannot be deleted.

No – assigned access levels can be deleted.

6Assigned Time Zones checkboxSettings checkboxForbids to delete time zones if they are assigned to access levelsBoolean typeNo

Yes – assigned time zones cannot be deleted.

No – assigned time zones can be deleted.
Out of groups
7Allow user type change checkboxSettings checkboxEnables the ability to change the user typeBoolean typeNo

Yesthe user type change is allowed.

Nothe user type change is not allowed.

Access cards tab

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

Minimum drop-down listSelecting the value in the listSets the minimum number of access cards that should be assigned to the userList of valuesUnlimited
  • from 1 to 5 - if the specified number of access cards is not assigned to the user, then this user cannot be saved in the Access Manager interface object.

  • Unlimited - an unlimited number of access cards can be assigned to the user.

  • Prohibited - the user cannot be assigned access cards. Buttons and functional menu for assigning access cards will be inactive in the Access Manager interface object.

2Maximum drop-down listSelecting the value in the listSets the maximum number of access cards that should be assigned to the userList of valuesUnlimited
  • from 1 to 5 - if the user is assigned more than the specified number of access cards, then this user cannot be saved in the Access Manager interface object.

  • Unlimited - an unlimited number of access cards can be assigned to the user.

  • Prohibited - the user cannot be assigned access cards. Buttons and functional menu for assigning access cards will be inactive in the Access Manager interface object.

3Common format drop-down listSelecting the value in the listSets the access cards formatList of valuesDefault
  • Default - allows setting an arbitrary value for the facility code and card code. Any letters, numbers and symbols are allowed except: <| >.

  • Wiegand26 - allows entering a 1-byte facility code (from 0 to 255), and a 2-byte card code (from 0 to 65535).

  • Wiegand32 - allows entering a 2-byte facility code (from 0 to 65535), and a 2-byte card code  (from 0 to 65535).

  • Wiegand26 (code only) - the facility code cannot be set, only a 3-byte card code is set (from 0 to 16777215).

  • Wiegand32 (code only) - the facility code cannot be set, only a 4-byte card code is set (from 0 to 4294967295).

  • TouchMemory - the facility code cannot be set, only the 8-byte card code is set. The format is hexadecimal, characters A, B, C, D, E, F are allowed. The code should be 8 characters or longer. If the entered card code is less than 8 characters long, the the higher order digits are filled with zeros.

  • Hikvision - the Hikvision ACS format. It always has a fixed H character in the facility code. The card code is specified by a string with a maximum length of 32 characters.

  • Configurable - allows setting the parameters of the facility code (4) and card code (5).

    • Fixed character - the specified single character will always be hard-coded, which cannot be changed in the Access Manager interface object.

    • String - allows entering a string of 0 to 255 characters.

    • Numeric - allows entering only numbers from 0 to 4294967295.

    • Hexadecimal - allows entering numbers in HEX format (numbers and symbols A, B, C, D, E, F) from 0 to 8 bytes long.

    • Fixed number - similar to Fixed character, but instead of a character, a number between 0 and 4294967295 is used.

    • Regular template - allows defining an access card template with specified restrictions, lengths and value ranges.

Readers tab

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

Confirm card entered by operator checkbox

Settings checkbox

Sets requirement  to confirm card code entering by operator

Boolean type

No

Yes – operator confirmation is required  to assign access card to user.

No –operator confirmation is not required to assign access card to user.

2

List of readers

Settings checkbox

Sets list of control readers used for entering user access cards

List of created reader objects in the system

Set of boolean variables

The reader will be available to enter user access card if checkbox is set close to it

Cameras tab


Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

Cameras column

Automatically

Displays list of Camera objects created on the Hardware tab of the System settings dialog window

List of created Camera objects in the system

Names of Camera objects

Depends on number of accessible Camera objects in the system

2

Use checkbox

Settings checkbox

Sets possibility to use camera for assigning photo to user in the Access Manager window

Boolean type

No

Yes – camera can be used for assigning photo.

No – camera can't be used for assigning photo

3Compression drop-down listSelecting the value in the listSets the compression level of the selected video stream-Do not compress

Do not compress - compression of the camera video stream is disabled

Level 1 - the lowest level of video stream compression

....

Level 5 - the highest level of video stream compression

4

Gateway drop-down list

Selecting the value in the list

Sets the Gateway object used for receiving video signal from camera

List of created Gateway objects in the system

Names of Gateway objects

Depends on number of accessible Gateway objects in the system

Others tab

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

Full name drop-down list

Selecting the value in the list

Sets the way of defining of users record duplicates by name, surname, patronymic

List of available combinations

Not used

 Not used – adding users with the same full name is allowed.

Surname, name – adding users with the same name and surname and different patronymic is  forbidden.

Surname, name, patronymic – creating users with the same full name is forbidden.

2External ID checkboxSettings checkboxIndicates whether the users records should be checked for external ID duplicatesBoolean typeNo

Yescreating users with the same external ID is forbidden.

Nocreating users with the same external ID is allowed.

3PIN code checkboxSettings checkbox



4Vehicle license plate checkboxSettings checkboxIndicates whether the users records should be checked for vehicle license plate number duplicatesBoolean typeNo

Yes – creating users with the same license plate number is forbidden.

No – creating users with the same license plate number is allowed.

5Recognition Server drop-down listSelecting the value in the listDisplays a list of Face Recognition Server objects created on the Hardware tab of the System Settings dialog boxList of Face Recognition Server objects created in the system-Depends on number of accessible Face Recognition Server objects in the system
6RestAPI port fieldSetting the value in the fieldSpecifies the communication port to connect to the Face Recognition Server through the REST API. By default, it is necessary to set the 10000 value.Number0-

Standard fields tab

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

Name of field columnAutomaticDisplays a list of standard user fields-Names of standard user fields-
2Drop-down listSelecting the value in the listSpecifies the permissions to edit, specify, or hide the standard fields from the Access Manager interface object-Depends on the standard field

Edit - the field is displayed in the list of user parameters while viewing and editing and is available for editing

Hidden - the field is not displayed in the list of user parameters while viewing and editing

Read only - the field is displayed in the list of user parameters while viewing and editing but is not available for editing

Mandatory - this field is displayed and is required when creating a new user

3Category columnSetting the value in the fieldSpecifies the name of the category to which the standard field belongs-Depends on the standard fieldAny value

Additional fields tab

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

Name of field columnAutomaticDisplays a list of additional user fields-Names of additional user fields-
2Drop-down listSelecting the value in the listSpecifies the permissions to edit, specify, or hide the additional fields from the Access Manager interface object-Depends on the additional field

Edit - the field is displayed in the list of user parameters while viewing and editing and is available for editing

Hidden - the field is not displayed in the list of user parameters while viewing and editing

Read only - the field is displayed in the list of user parameters while viewing and editing but is not available for editing

Mandatory - this field is displayed and is required when creating a new user

3Category columnSetting the value in the fieldSpecifies the name of the category to which the additional field belongs-Depends on the additional fieldAny value