Biometric parameters can be added to the Access Manager module from the DCR-PV reader and the Biosmart PV-WTC terminal.
Before start, you need to configure the interaction of the DCR-PV USB control reader connected to the BioSmart UniPass controller, as well as the Biosmart PV-WTC terminal with the Access Manager module (see Configuring interaction of BioSmart UniPass module with Access Manager and Time&Attendance modules).
Adding biometric parameters using the Biosmart PV-WTC terminal
To add biometric parameters follow these steps:
- Go to adding biometric data in the Access Manager window (see Adding biometric parameters).
- Select the appropriate extension: (Biosmart Palm Vein) Biosmart WTC.
The Operations on biometrics dialog box appears. Click Add templates
Note
The Delete all the templates button removes all palm templates.- The Reading biometric data dialog box appears. Follow the instructions on the terminal screen.
- If the palm template is successful, a message will be displayed.
- Click Apply to save the template.
- You can add as many templates as the terminal configuration allows (see Configuring BioSmart UniPass and Biosmart PV-WTC). The Operations on biometrics window displays the number of saved templates.
Adding biometric parameters using the DCR-PV USB control reader
To add biometric parameters follow these steps:
- Go to adding biometric data in the Access Manager window (see Adding biometric parameters).
- Select the appropriate extension: (Biosmart Palm Vein) Biosmart Palm Scanner (reader DCR-PV).
The Operations on biometrics dialog box appears. Click Add templates
Note
The Delete all the templates button removes all palm templates.- The Reading biometric data dialog box appears. Next step is to put your palm to the reader.
- Then you have to apply the same palm again.
- If the operation is successful, the message Biometric data is successfully received will appear.
- Click Apply to save the template.