Documentation for Auto Intellect 5.6. Documentation for other versions of Intellect is available too.

Previous page ARENA module licensing  External Plates DB Next page


Note

When the ARENA program module is used, the LPR channel parent object should not be set up.

The ARENA program module provides interaction of velocimeter and Arena photo fixation (Arena integrated circuit) and Auto Intellect.

Arena integrated circuit is a monobloc unit containing inside the following devices:

  1. Radar;
  2. Camera;
  3. Computer with installed and set up ftp-server;
  4. Data storage;
  5. Devices, providing Arena integrated circuit workability

Note

Detailed information about Arena integrated circuit is given in official reference manual.

The Auto Intellect server requires photos with a stated period of time from Arena integrated circuit. In case when the Auto Intellect server and Arena integrated circuit are disconnected and then the connection is restored, the photos made during the connection loss will be downloaded from the ftp-server.

Note

When the Arena web interface is closed incorrectly, Auto Intellect complex stops receiving events.

To set up the ARENA program module, the following data about the Arena integrated circuit are necessary:

  1. IP address of the Arena computer with installed and set up ftp-server;
  2. Port for connection to the ftp-server;
  3. Username and password for connecting to the ftp-server.

Setting up ARENA program module is performed in the following way:

  1. Go to the ARENA module object settings panel, which is created on the basis of the LPR channel object (2).
  2. In the IP address field, enter the IP address of the Arena computer with installed ftp-server (3).
  3. In the FTP port field, enter the port for connection to the ftp-server (3). Port 21 is used by default.
  4. In the TCP/IP port field, enter the TCP/IP port for connection to the ftp-server (3). Port 6008 is used by default.
  5. In the Login (4) and Password (5fields, enter the username and password for connection to this ftp-server.
  6. In the Frames polling interval, ms field, enter the time between two one by one requires of Auto Intellect for downloading the photos from the Arena integrated circuit (6).
  7. In the Alarm on speed limit, km/h field, enter the maximum available vehicle speed in km/h (7). In case, when the vehicle moves at a speed above the maximum available vehicle speed, the system generates the report about the excessive speed.
  8. Click the Apply button (8).

Setting up the ARENA module is completed.