Documentation for Face Intellect 7.4. Documentation for other versions of Intellect is available too.
The firserver.log log file of the Face Recognition Server debug window is located at the following path: <Face Intellect installation directory>\Modules64\. This log file stores all events from the Face Recognition Server object.
An example of the firserver.log file contents:
To enable logging of each face capture event, it is necessary to change the value of the FaceTracker.LogTrackerQuality key to 1 (for details, see the Registry keys reference guide, for more information about working with the registry, see Working with Windows OS registry). As a result, the events of each face capture will be recorded in the log file firserver.log.
An example of a face capture event:
FaceDetector 1.1, track: 27, quality: ok(current = 0.73, threshold = 0.23), total: 645, filtered(ok): 455.
The event parameters are described in the table below:
Parameter | Description |
---|---|
track | Current track number |
quality | Captured face quality: ok for good quality, low for bad quality (current < threshold) |
current | Captured face quality determined by the math calculation |
threshold | Minimum face quality set in the Face Recognition Server object settings panel |
total | Number of all captured faces |
filtered(ok) | Number of all good quality faces that passed the filter (current >= threshold) |
Note
The total and filtered(ok) numbers are calculated anew each time after applying the settings in Face Intellect.