Documentation for Axxon Next 4.4.6. Documentation for other versions of Axxon Next is available too.

Previous page Console utility for working with archives  Appendices Next page

The utility executable is located in the <Axxon Next installation directory\bin> folder. 

The utility allows you to:

  1. Set the external address of the switch if the Server is located behind the NAT (1). Use the following settings format: "IP Address 1 or DNS Name 1, IP Address 2 or DNS Name 2"
  2. Set the port range for operation of the Axxon Next Server (2-3). To do this, specify the beginning of the range and the number of ports. The number of ports should not be lower than 20. 

    Attention!

    Within an Axxon Domain, the port ranges of Servers should not overlap.

    Note

    The number of ports that you select affects the scalability of the system. Keep the following in mind when specifying the number of ports:

    6 ports  is a minimum system requirement for machines with Axxon Next.

    - In a 32-bit configuration, for every 32 cameras, 6 ports are required (for multistreaming cameras). In a 64-bit configuration, for any number of cameras, 6 ports are required.

    2 ports are required to write to the archive.

    - To use the Object Tracking database (track recording), 1 port is required.

    - To use basic detection tools, 2 ports are required.

    - To use Scene Analytics, 2 ports are required.

    - To use E-mail- (through SMTP), SMS or server audio notification 1 port is required .

  3. Restrict the visibility of Servers from various networks in the Servers list during the Axxon Next setup (4). Possible values:
    1. "0.0.0.0/0" -  Servers from all networks will be visible.
    2. "10.0.1.23/32,192.168.0.7/32" - Only Servers from specified networks will be visible.
    3. "127.0.0.1" - Only Servers from the local network will be visible.

After you save the settings, the Server will be restarted.