Go to documentation repository
Documentation for Axxon One 1.0.
You can set a number of specific parameters which affect triggering a face recognition macro:
- Age of the individual (requires activation of the Gender and Age parameter, see Configuring Face detection).
- Gender of the individual (requires activation of the Gender and Age parameter, see Configuring Face detection). Value: 1 = female, 2 = male.
- TemperatureValue: body temperature of the individual (requires the Face Detection and Temperature Control, see Face Detection and Temperature Control with Mobotix M16 TR cameras).
To set specific parameters, do the following:
- Select Faces: Specified triggering event as a launch condition.
- Click .
Specify a required parameter value in the corresponding field (1).
Attention!
The parameter is case-sensitive.
In the Value (2) and Max value (3) fields, set the range of parameter values within which the macro will be triggered.
Note
Examples.
If you set Age to [18, 100], the macro will be triggered only if the detection tool returns the age value of 18 or more.
If you set Gender to [1, 1], the macro will be triggered only if the detection tool returns the individual's gender as female.
If you set Gender to [2, 2], the macro will be triggered only if the detection tool returns the individual's gender as male.
If you set TemperatureValue to [37, 100], the macro will be triggered only if the detection tool returns the temperature value of 37 or more.
- Add one or more actions into the macro (see Settings specific to actions).
- Click the Apply button.