Go to documentation repository
Documentation for Intellect Web Report System 3.5. Documentation for other versions of Intellect Web Report System is available too.
Setting up the Video Player is necessary in the following cases:
- To be able to view the video archive of events in browsers based on the Blink and Gecko browser engines (Google Chrome, Yandex Browser, Firefox, Opera, etc.).
- To display frames from cameras in the built general Report by camera.
The Video Player is configured as follows:
- Go to the General tab > VideoPlayerSettings.
- In the Host_Web field (1), enter the IP address of the Server on which the Web-server module is configured (for details, see Configuring the Web-server module). Default: http://localhost.
In the Port field (2), enter the port number for connecting to the HTTP server, which is specified on the settings panel of the Web-server object (see Setting the parameters of connecting Clients to the Web-server).
Note
If the Web-server module is configured on the same Server where the Intellect Web Report System is installed, then the Port value is filled in automatically after restarting the Cassini Service.
- In the User (3) and Password (4) fields, enter the username and password for the Intellect user, who has the rights to perform video surveillance from a Web browser. If you log into Intellect without authorization, leave the field blank.
- Click Save (5) to apply the changes.
The video player is configured.
Overview
Content Tools