Configure special operation mode on Server of Control as follows:
- Create and configure Server of Control object on the Hardware tab (see Configuring Server of Control).
- Create and configure one or several External plates DB objects on the Hardware tab (see Connecting and setting up of the external LP number database).
- Create and configure Monitoring object on the Interfaces tab (see Configuring the Monitoring interface object).
- Create ULPR section in the Windows registry if it is not created yet (see Registry keys reference guide for more details on the key, see Working with Windows OS registry for more details on how to operate registry).
- In the ULPR section of the Windows registry create ULPRspecialProcessing string parameter and set it to 1 (see Registry keys reference guide for more details on the key, see Working with Windows OS registry for more details on how to operate registry).
- Restart the computer to apply changes.
As a result, the Info on vehicle license plates button becomes available in the Log panel and Details window of the Monitoring interface. The License plate search window opens when clicking this button (see Viewing recognized LPs).
Note.
By default, the LP found in the database alarm is generated for Entrance recognition point only. In order to generate alarm both on Entrance and Exit points, in the ULPR section of the Windows registry create AlarmMsgOne string parameter and set it to 0 (see Registry keys reference guide for more details on the key, see Working with Windows OS registry for more details on how to operate registry).
Configuring special operation mode on Server of Control is now completed.