Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.

Previous page FAQ: Frequently Asked Questions  What should I do if I'm getting the ‘Key file is not corresponding cards’ error when running? Next page


On the page:

Integrated IP devices

To check whether the required IP device is integrated into Intellect, do the following:

  1. Go to the Driver Pack documentation page.
  2. Download the list of supported IP devices (the latest release) in the xls format.
  3. Open the file and go to the Intellect tab. 
  4. If the IP device is present in the list and the specified firmware in the file is the same as the current device firmware, it means the device is integrated.    

    The full article: Camera discovery tool

  5. If the IP device is not present in the list but it is known that it supports some common protocols (General device, ONVIF, RTSP), connect the device via these protocols:
    1. The General device generic drivers allow the AxxonSoft products to practically operate with all the devices of the corresponding vendor.

    2. Before connecting via the ONVIF protocol, check the device operation in the ONVIF Device Manager utility. If you can get the IP device video in this utility, then the device can be connected to Intellect.

    3. Before connecting via the RTSP protocol, check the device operation in the VLC Media Player utility. If you can get the IP device video in this utility, then you can connect the device to Intellect.

Integrated ACS/FSA/PIDS

To check whether the required Access Control System (ACS), Fire Security Alarm (FSA) and Perimeter Intruder Detection System (PIDS) are integrated into Intellect, go to ACFA Intellect List of Integrated Equipment and find the required system in the list.

The integrated systems connection setting is described in the documentation on the corresponding integration module. The full list of documents is available on the page.

If the system is not present in the list but it is known that it supports the general-purpose protocols (OPC, BACnet, SNMP), connect this system via these protocols.


Integrated cash register system and truck scales

To check whether the required cash register system or truck scales are integrated to POS-Intellect, go to Equipment/Hardware integrated into the POS-Intellect Software and find the required system in the list.

If the system is not present in the list, the connection setting is executed on the POS-terminal object setup panel.

If the system is not present in the list, you can put in a request for integration.

You can also implement the integration on your own using the POS SDK.