Documentation for Auto PSIM 1.0.1.

Previous page Next page

Attention!

Allowable error at determining the number of vehicles is 10% and allowable error at vehicle types recognizing is 15%. Errors determination is performed while moving not less than 1000 vehicles in the camera field of view.

Setting up the IV vehicle detection parameters is done in the following way:

  1. Execute the IV vehicle detection setup with the TestAppTMD.exe utility (see TestAppTMD.exe utility for setting up the IV vehicle detection).
  2. Go to the IV vehicle detection object setup panel which is created on the base of the Computer object on the Hardware tab of the System settings dialog box.
  3. From the Camera dropdown list select the Camera object, corresponding to the camera of the IV vehicle detection (1).

  4. Click the button (2) and select the setup file in the JSON format created with the TestAppTMD.exe utility.

  5. To save the applied changes click Apply (3).

Setting up the IV vehicle detection parameters is completed.

  • No labels