To configure the Emulator ACFA integration module, do the following:

  1. Go to the settings panel of the Emulator ACFA object.

  2. In the Address field, enter the local IP address of the computer. In future versions, it will be possible to specify the IP address of the computer for remote connection and control of the Emulator ACFA integration module.
  3. In the Auth token field, specify a token for logging into Swagger software—a framework that allows you to automatically describe APIs based on its code (non-editable field).
  4. In the Configuration settings section:
    1. In the ACS units field, specify the number of ACS (Access Control System) objects. The default value is 20. One object consists of one lock and two readers (child objects). You cannot change the number of child readers of one lock.
    2. In the Download delay, s field, specify the interval in seconds between the creation of two objects. The default value is 0. We don’t recommend changing it.
    3. In the Fence units field, specify the number of PID (Perimeter Intrusion Detection System) of the Virtual fence objects. The default value is 20.
    4. In the FSA units field, specify the number of FSA (Fire and Security Alarm) of the Virtual sensor objects. The default value is 20.
    5. In the Generate exception field, select from the drop-down list at what point during download an error is generated:
      1. No (default),
      2.  At the beginning,
      3. In the middle,
      4. At the end.
    6. In the loop units field, enter the number of Virtual loop objects. The default value is 20.

      Note

      After you download the configuration, six Virtual input and six Virtual output objects are created on the basis of the Virtual loop object.

    7. In the Zone group units field, enter the number of Virtual zone group objects. The default value is 20.
  5. In the Server settings section:
    1. In the Server port field, specify the port number via which Swagger software is available.
    2. In the Enable swagger UI field, select from the drop-down list Enabled to activate Swagger software in the browser. By default, Swagger is disabled in the browser (the Disabled value is selected).
    3. In the Server is active field, select from the drop-down list Enabled to activate Swagger software. By default, Swagger is disabled (the Disabled value is selected).
  6. Click the Apply button to save the changes.
  7. Click the button and select Download configuration from the drop-down list to automatically download the configuration and build the hardware tree.
  8. Click the Apply button.

Configuration of the Emulator ACFA integration module is complete. As a result, the hardware tree will be built according to the configuration specified in the previous steps: