The GRAY object corresponds to the Sensor system object.

The GRAY object sends events presented in the table. Procedure is started when the corresponding event occurs.

Event

Event description

ALARM

Alarm. This event is received when the sensor is opened or closed (it depends on object settings) if sensor is armed. If sensor is disarmed, then Sensor opened and Sensor closed events are received respectively

ARM

Sensor is armed

CONFIRM

Alarm received

DISARM

Sensor is disarmed

NOT_VALID_STATE

Zone is not ready

OFF

Sensor is opened. This event is received when the sensor is opened if the sensor is disarmed

ON

Sensor is closed. This event is received when the sensor is closed if the sensor is disarmed

SIGNAL_LOST

Connection with the sensor is lost

List of commands and parameters for the GRAY object is presented in the table:

Commandcommand description

Parameters

Description

"ARM"arm the sensor

-

-

"DISARM"disarm the sensor

-

-

“CONFIRM”confirm an alarm

-

-

“SETUP”settings for the sensor

chan<>

Output number (0–15)

flags<>

Flags

name<>

Object name

type<>

Type of sensor object (0on closing, 1on opening)

Properties of the GRAY object are shown in the table.

Properties of the GRAY object

Description of properties

ID<>

Object ID

PARENT_ID<>

Parent object ID

REGION_ID<>

Region ID

The GRAY object can be in the following states:

State of the GRAY object

State description

"ARMED"

Sensor is armed

"DISARME"”

Sensor is disarmed

"ALARMED"

Alarm

"CONFIRMED"

Alarm confirmed

"DISARMED_ALARM"

Not ready

"DETACHED_ARMED"

Connection lost when the sensor was armed

"DETACHED_DISARM"

Connection lost when the sensor was disarmed

“OFF”

Normal