Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page Next page


The settings panel of the SIP-device system object is shown in the figures below.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the SIP-device system object in the system

Digits, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the SIP-device objects in the system

2

The Name*
field

Enter the value in the field

Sets the name of the SIP-device object system

Latin alphabet, Cyrillic, digits and service characters

SIP-device

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Disables the SIP-device object in the system

Boolean type

Clear

Setthe SIP-device object is disabled and isn't used

Clearthe SIP-device object is enabled and used

4

The SIP-terminal
drop-down list

Select the value from the list

Sets the SIP-terminal parent object for the given SIP-device object

Names of the SIP-terminal objects registered in the system

Name of the SIP-terminal parent object

Depends on the number of the SIP-terminal objects in the system

5The Device type
drop-down list
Select the value from the listSets the icon type to display the device on the mapNames of the available icon typesEmpty line 
  • Empty line (no value);
  • touch panel;
  • speaker;
  • camera;
  • microphone;
  • default
6The Device priority
drop-down list
Select the value from the list

Sets the priority of a call from this device in the incoming calls window of the SIP panel

Sequence of numbersEmpty line

From 1 to 10.

  • The lower the number, the higher the priority and, accordingly, the higher the display in the list;
  • If the field is left blank, then the priority is considered to be minimal;
  • Calls from devices with the same priority are sorted by the time of the call
The Device connection settings group
7The User ID
field
Enter the value in the fieldSets the SIP device identification number, that is, the number to call itInteger numbersNA>=0
The Device IP address
field
Enter the value in the field

Enters the SIP device IP address.

For the SIP-server terminal type only

IP addressNAFrom 1.0.0.0 to 255.255.255.255
The Password
field
Enter the value in the field

Sets the password to connect to the SIP device.

For the SIP-server terminal type only

Latin alphabet, Cyrillic, digits and service charactersNAA line containing a sequence of any characters (letters, digits, service characters)
The State
field
Automatically

Displays the SIP device state.

For the SIP-server terminal type only

NANANA

*Name of the element isn't displayed in the settings panel of the given object

The Video/Audio tab (only for the SIP-server terminal type)

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1The Video
switch
Set the switch to the required positionSets the camera used for callsSupported options of camera usageOff
  • Off—video isn't used during the call;
  • SIP camera—the SIP device camera connected via the SIP protocol is used;
  • Other—any other camera from the Axxon PSIM hardware tree selected from the Camera drop-down list is used
2The Camera
drop-down list
Select the value from the listSets any camera used for calls

Names of the Camera objects registered in the system

NADepends on the number of the Cameras objects in the system
3The Audio
switch
Set the switch to the required position

Enables the audio during a call

Supported options of audio usageOff

Off—the audio isn't used during the call

On—the microphone of the SIP device is used during the call

4The Microphone
field
AutomaticallyDisplays the name of the Microphone object corresponding to the SIP deviceNANANA

The Relay tab (only for the SIP-server terminal type)

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1The DTMF type
drop-down list
Select the value from the listSets the type of the tone signalSupported signal typessip_info
  • sip_info—signals are transmitted in the INFO message of the SIP protocol;
  • sip_notify—signals are transmitted in the NOTIFY message of the SIP protocol;
  • in_band—the signal is transmitted as normal sound in the audio stream;
  • http_bassignals are transmitted via the HTTP protocol separately from the voice stream
2The Signal duration, ms fieldEnter the value in the fieldSets the time period in milliseconds during which the DTMF signal must be sentSequence of numbersNA>0
3The Name
field
Enter the value in the fieldSets the name of the command that will be displayed on the SIP panel Latin alphabet, Cyrillic, digits and service charactersNAA line containing a sequence of any characters (letters, digits, service characters)
4The Code
field
Enter the value in the fieldSets the unique command codeSequence of numbers or HTTP request (for http_bas)NA

A line containing a sequence of numbers or HTTP request

5The Device connection settings
field
NAOpens the Device connection settings pop-up window only when the http_bas type of tone is selected NAInactive by defaultNA

The table below describes the fields of the Device connection settings pop-up window.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1The Login
field
Enter the value in the fieldSets the username to connect to the SIP device (BasIP)Latin alphabet, Cyrillic, digits and service charactersNAA line containing a sequence of any characters (letters, digits, service characters)
2The Password
field
Enter the value in the fieldSets the password to connect to the SIP device (BasIP)Latin alphabet, Cyrillic, digits and service charactersNAA line containing a sequence of any characters (letters, digits, service characters)
3The IP address
field
Enter the value in the fieldSets the IP address of the SIP device (BasIP)IP addressNAFrom 1.0.0.0 to 255.255.255.255