Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page Next page


The settings panel of the SIP-operator system object is shown in the figures below.

The table describes the setting parameters of the SIP-operator system object.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the SIP-operator object in the video surveillance system with distributed architecture

Digits, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the SIP-operator object in the video surveillance system with distributed architecture

2

The Name*
field

Enter the value in the field

Sets the name of the SIP-operator object in the video surveillance system with distributed architecture

Latin alphabet, Cyrillic, digits, and service characters

SIP-operator

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of characters—from 1 to 60

3

The Disable
checkbox

Set the checkbox

Disables the SIP-operator object in the video surveillance system with distributed architecture

Boolean typeClear

Setthe SIP-operator object is disabled and isn't used

Clearthe SIP-operator object is enabled and used

4The SIP-terminal
drop-down list
Select the value from the listSets the SIP-terminal parent object of the system with distributed architecture to which the given SIP-operator object belongsNames of the SIP-terminal objects registered in the systemName of the SIP-terminal parent objectDepends on the number of the SIP-terminal objects in the video surveillance system with distributed architecture
5The Device priority
drop-down list
Select the value from the listSets the priority of a call from this operator in the incoming calls window of the SIP panelSequence of numbersClear

From 1 to 10.

  • The lower the number, the higher the priority and, accordingly, the higher the display in the list;
  • If the field is left blank, then the priority is considered to be minimal;
  • Calls from operators with the same priority are sorted by the time of the call

The User group

6

The Number
field
 

Enter the value in the field

Sets the identification number of the operator to which you can call

Digits, letters, periods, hyphen, dash, and underscore

NA

A line containing a sequence of any characters (numbers, letters, periods, hyphens, dash, and underscore)

7The Bind operator to user rights
checkbox
Set the checkbox

Enables binding of an SIP operator to Axxon PSIM user rights. Activates the User drop-down list.

Note. It is used when you select the default operator on the SIP panel to which the user rights are assigned

Boolean typeClear

Setbinding of an SIP operator to Axxon PSIM user rights is enabled

Clearbinding of an SIP operator to Axxon PSIM user rights is disabled

8The User
drop-down list
Select the value from the listSets the user under which you must register in Axxon PSIM

Names of the User objects registered in the system

NADepends on the number of the User objects in the system

*Name of the element isn't displayed in the settings panel of the given object

The Server connection tab (only for the SIP-client terminal type)

The table describes the setting parameters of the Server connection tab.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1The Login
field
Enter the value in the field

Sets the username for connecting to the SIP server.

Only for the SIP-client terminal type

Latin alphabet, Cyrillic, digits, and service charactersNAA line containing a sequence of any characters (letters, digits, service characters)
2The Password
field
Enter the value in the field

Sets the password for connecting to the SIP server.

Only for the SIP-client terminal type

Latin alphabet, Cyrillic, digits, and service charactersNAA line containing a sequence of any characters (letters, digits, service characters

The Address book tab

The table describes the setting parameters of the Address book tab.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

The Address books table
1The Number
drop-down list
Select the value from the listSelects the identifier of the Address book objectIdentifiers of the Address book objects registered in the systemNADepends on the number of the Address book objects in the system
The Name
drop-down list
Select the value from the listSelects the name of the Address book object in Axxon PSIM, the numbers of which are available for this SIP operatorNames of the Address book objects registered in the systemNADepends on the number of the Address book objects in the system
2The All buttonClick the buttonAdds all existing Address book objects to the tableNANANA
3The Range
button
Click the buttonOpens the Add address books window to add several address booksNANANA