Documentation for Axxon PSIM 2.0. Documentation for other versions of PSIM is available too.

Previous page Next page


The settings panel of the Charts interface object is shown in the figure.

The table describes the setting parameters of the Charts interface object.

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range

1

The Identification number*
field

Automatically

Displays the identification number of the Charts object in the system

Numbers, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the Charts objects in the system

2

The Name*
field

Enter the value in the field

Sets the name of the Charts object in the system

Latin alphabet, Cyrillic, numbers, and service characters

Charts

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Disables the Charts object in the system


Boolean type

Clear

Setthe Charts object is disabled and isn't used

Clearthe Charts object is enabled and used

4

The Display
drop-down list

Select the value from the list

Sets the Display parent object for the given Charts object 

Names of the Display objects registered in the system

Name of the Display parent object

Depends on the number of the Display objects in the system

The Position group

5

The X field

Enter the value in the field

Sets the X coordinate in the horizontal axis for the upper left corner of the Charts window

% of the screen width

44

From 0 to M*100, where M is the number of the installed monitors

The Y field

Enter the value in the field

Sets the Y coordinate in the vertical axis for the upper left corner of the Charts window

% of the screen height

44

From 0 to M*100, where M is the number of the installed monitors

The W field

Enter the value in the field

Sets the width of the Charts window 

% of the screen width

44

From 0 to M*100, where M is the number of the installed monitors

The H field

Enter the value in the field

Sets the height of the Charts window 

% of the screen width

44

From 0 to M*100, where M is the number of the installed monitors

The Allow moving
checkbox

Set the checkbox

Allows moving the Charts window using the mouse

Boolean type

Clear

Setallow moving the Charts window using the mouse

Cleardisable moving the Charts window using the mouse

The button

Click the button

Opens the window for setting the position and size of the Charts window

NANANA
The Monitor
drop-down list
Select the value from the listDetermines the number of the monitor in the system for which the coordinates are specifiedNumbers of the monitors in OS1From 1 to 16
The Objects table
6The Number
drop-down list
Select the value from the list

Sets the identifier of the Analog sensor object, the data from which must be displayed in the chart

Names of the Analog sensor objectsNA

Depends on the Analog sensor objects in the system

The Name
drop-down list
Select the value from the listSets the name of the Analog sensor object, the data from which must be displayed in the chart
Names of the Analog sensor objectsNADepends on the Analog sensor objects in the system
The Color
drop-down list
Select the value from the list

Sets the display color of the corresponding analog sensor in the chart in the Charts window

Color paletteBlackRGB color
The Line width fieldEnter the value in the field

Sets the width of the line in the chart

Sequence of numbers5>0

Out of the group

7The Number of pixels
field
Enter the value in the fieldSets the number of pixels to be displayed in the chartInteger numbers0>=0

*Name of the element isn't displayed in the settings panel of the given object