Documentation for Axxon PSIM 2.0. Documentation for other versions of PSIM is available too.

Previous page Next page


The Event counter object is used to register and count Axxon PSIM events at selected objects of a specified type.

The settings panel for the Event counter object is shown in the figure.

The table describes the setting parameters corresponding to the elements of the settings panel of the Event counter object.

 

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number* field

Automatically

Displays the identification number of the Event counter object in the video surveillance system with the distributed architecture

Digits, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the Event counter objects in the video surveillance system with the distributed architecture

2

The Name* field

Enter the value in the field

Sets the name of the Event counter object in the video surveillance system with the distributed architecture

Latin alphabet, Cyrillic, digits and service characters

Event counter

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable checkbox

Set the checkbox

Disables the Event counter object in the video surveillance system with the distributed architecture

Boolean type

Clear

Set—the Event counter object is disabled

Clearthe Event counter object is enabled

4

The Computer
drop-down list

Select the value from the list

Sets the Computer parent object of the system with the distributed architecture to which the given Event counter object belongs

Names of the Computer objects registered in the system

Name of the Computer parent object

Depends on the number of the Computer objects in the video surveillance system with the distributed architecture

The Start counting group

5

The From (activation)
checkbox

Set the checkbox

Allows setting manually the date and time of the count start



Boolean type

Set

Set—the date and time of the count start are set manually

Clear—the date and time of the count start are set at the date and time when the Event counter object was last modified

The From (date) 
field/drop-down list

Enter the value in the field/ select the value from the list

Sets the date of the count start

date:month:year

The current system date value

01.09.1752—01.12.9999

The From (time) field

Enter the value in the field

Sets the time of the count start

hours:minutes:seconds

The current system time value

00:00:00—23:59:59

6

The From the moment counter settings are changed
checkbox

Set the checkbox

Sets the date and time of the count start at the date and time when the Event counter object was last modified

Boolean type

Clear

Set—the date and time of the count start are set at the date and time when the Event counter object was last modified

Clear—the date and time of the count start are set manually

7

The One counter for all events checkbox

Set the checkbox

Sets the same counter for all events presented in the Objects group and events of the given Event counter object

Boolean type

Set

Set—only one counter is used for counting all events specified in the Objects group

Clear—different events are counted by different counters (each event is counted by a separate counter)

The Signal group

8


The Counter notification group*

The By time (activation)
checkbox

Set the checkbox

Enables a regular notification in a set period of time


Boolean type

Set

Setthe notification by time is enabled

Clear—the notification by time is disabled (notification by quantity of events is enabled)

The By time (every)
field

Enter the value in the field

Sets the notification period as a time interval.
Notification is performed regardless of the count start time at 00 minutes 00 seconds of every hour (or at 00 hours 00 minutes 00 seconds of every day, depending on the "time unit" settings)

Integer numbers

0

0—2147483648

The By time (time unit)
drop-down list

Select the value from the list

Sets a time unit for the notification

Line

Hours

Hours

Days

The By quantity of events (activation)
checkbox

Set the checkbox

Enables a regular notification about events starting from the set one

Boolean type

Clear

Set—the notification by the quantity of events is enabled

Clear—the notification by the quantity of events is disabled (the notification by time is enabled)

The By quantity of events (quantity of events)
field

Enter the value in the field

Sets the number of the event starting from which the notification is performed.

Example: if the parameter has the 5 value, then notification is performed by every event starting from 5 (5, 6, 7, 8, and so on)

Integer numbers

0

0—2147483648

9


The Reset counters group*

The Reset counters
checkbox

Set the checkbox

Enables counters reset

Boolean type

Clear

Set—counters reset is enabled

Clear—counters reset is disabled

The By time (activation)
checkbox

Set the checkbox

Enables a cyclic counter reset in a set time period



Boolean type

Set

Set—a cyclic reset in a set time period is enabled

Clear—a cyclic reset in a set time period is disabled (a cyclic reset by the quantity of events is enabled)

The By time (every)
field

Enter the value in the field

Sets a reset period as a time interval.

Reset is performed regardless of the time of the count, starting at 00 minutes 00 seconds of every hour (or at 00 hours 00 minutes 00 seconds of every day, depending on the "time unit" settings)

Integer numbers

0

0—2147483648

The By time (time unit)
drop-down list

Select the value from the list

Sets a time unit for the counters reset

Line

Hours

Hours

Days

The By quantity of events (activation)
checkbox

Set the checkbox

Enables a counter reset when it reaches a specified number of event


Boolean type

Clear

Set—a cyclic reset after a specified number of events is enabled

Clear—a cyclic reset after a specified number of events is disabled (a cyclic reset after a specified period of time is enabled)

The By quantity of events (quantity of events)
field

Enter the value in the field

Sets a reset period for counters as the quantity of events

Integer numbers

0

0—2147483648

The Objects and events group*

10




The Object's type
drop-down list

Select the value from the list

Sets the type of object for which the events are counted



Names of the types of objects registered in the system

NA

Depends on the types of objects registered in the video surveillance system with the distributed architecture

11

The ID drop-down list

Select the value from the list

Sets the identification number of an object of the selected type for which the events are counted

Sequence of numbers


NA

Depends on the number of objects of the given type in the video surveillance system with the distributed architecture

12

The Object name
field

Automatically

Displays the identification number of the selected object

Latin alphabet, Cyrillic, and service characters

NA

Object name with the specified identifier

13

The Event
drop-down list

Select the value from the list

Sets an event that must be counted

Latin alphabet, Cyrillic, and service characters


NA

Depends on the types of objects registered in the video surveillance system with the distributed architecture

*Name of the element isn't displayed in the settings panel of the given object