Documentation for Axxon PSIM 2.0. Documentation for other versions of Axxon PSIM is available too.

Previous page Next page


The External window object is used to display the dialog window of various applications in the specified screen area. The applications can be either AxxonSoft applications or third-party applications.

The settings panel of the External window object is shown in the figure.

The table describes the setting parameters corresponding to the elements of the settings panel of the External window interface object.

 

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the External window object

Digits, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the External window objects

2

The Name*
field

Enter the value in the field

Sets the name of the External window object

Latin alphabet, Cyrillic, digits, and service characters

External window

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Disables the External window object 

Boolean type

Clear

Setthe External window object is disabled and isn't used

Clearthe External window object is enabled and used

4

The Display
drop-down list

Select the value from the list

Sets the Display parent object to which the given External window object belongs

Names of the Display objects registered in the system

Name of the Display parent object

Depends on the number of the Display objects

The Settings group
5

The X field

Enter the value in the field


Sets the X coordinate in the horizontal axis for the upper left corner of the window of the External window object on the screen

% of the screen width

60

From 0 to M*100, where M is the number of the installed monitors

The Y field

Enter the value in the field


Sets the Y coordinate in the vertical axis for the upper left corner of the window of the External window object on the screen

% of the screen height

50

From 0 to M*100, where M is the number of the installed monitors

The W field

Enter the value in the field

Sets the width of the window of the External window object

% of the screen width

40

From 0 to M*100, where M is the number of the installed monitors

The H field

Enter the value in the field

Sets the height of the window of the External window object

% of the screen width

40

From 0 to M*100, where M is the number of the installed monitors

The  button

Click the button

Opens the window for specifying the size and position of the External window object using the mouse

NA

NA

NA

The Monitor
drop-down list

Select the value from the list

Sets the number of monitor, which is used to display the window of the third-party application

Number of monitors

1

From 1 to 16

The Attachment field

Enter the value in the field

Sets the path to the application, which must be launched.

Note. All windows of the application are opened simultaneously if the application contains several windows

Latin alphabet, Cyrillic, digits, and service characters

NA

A line containing a sequence of any characters, case-insensitive.

Number of charactersfrom 1 to 250

The  button

Click the button

Displays the standard Windows dialog window to specify the path to the application that you must run

NANANA

*Name of the element isn't displayed in the settings panel of the given object