Documentation for Axxon PSIM 2.0. Documentation for other versions of Axxon PSIM is available too.

Previous page Next page


The Manager of failover services object is used to control the maximum number of the active failover services operating simultaneously in the distributed system. 

The settings panel of the Manager of failover services object is shown in the figure.

The table describes the setting parameters corresponding to the elements of the settings panel of the Manager of failover services object.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the Manager of failover services system object 

Digits, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the Manager of failover services objects in the video surveillance system with the distributed architecture

2

The Name*
field

Enter the value in the field

Sets the name of the Manager of failover services object in the video surveillance system with the distributed architecture

Latin alphabet, Cyrillic, digits and service characters

Manager of failover services

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Disables the Manager of failover services object in the system

Boolean type

Clear

Setthe Manager of failover services object is disabled and isn't used

Clearthe Manager of failover services object is enabled and used

4

The Maximum number of active failover services
field

Enter the value in the field

Sets the maximum number of inactive servers above which the migration of the configuration must be stopped until one of the busy failover services is released

>=0

0

0the maximum number of the simultaneously running failover services is unlimited

>0—the maximum number of the simultaneously running failover services is limited by the specified value

*Name of the element isn't displayed in the settings panel of the given object