Go to documentation repository
Previous page Next page
The settings panel of the SIP-panel interface object is shown in the figure.
The table describes the setting parameters of the SIP-panel interface object.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | The Identification number* field | Automatically | Displays the identification number of the SIP-panel object in the system | Numbers, letters, periods, hyphen, dash, and underscore | NA | Depends on the number of the SIP-panel objects in the system |
2 | The Name* | Enter the value in the field | Sets the name of the SIP-panel object in the system | Latin alphabet, Cyrillic, numbers, and service characters | SIP-panel | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | The Disable | Set the checkbox | Disables the SIP-panel object in the system | Boolean type | Clear | Set—the SIP-panel object is disabled and isn't used Clear—the SIP-panel object is enabled and used |
4 | The Display | Select the value from the list | Sets the Display parent object for the given SIP-panel object | Names of the Display objects registered in the system | Name of the Display | Depends on the number of the Display objects in the system |
The Position group | ||||||
5 | The X field | Enter the value in the field | Sets the X coordinate in the horizontal axis for the upper left corner of the SIP-panel window | % of the screen width | 0 | From 0 to M*100, where M is the number of the installed monitors |
The Y field | Enter the value in the field | Sets the Y coordinate in the vertical axis for the upper left corner of the SIP-panel window | % of the screen height | 45 | From 0 to M*100, where M is the number of the installed monitors | |
The W field | Enter the value in the field | Sets the width of the SIP-panel window | % of the screen width | 15 | From 0 to M*100, where M is the number of the installed monitors | |
The H field | Enter the value in the field | Sets the height of the SIP-panel window | % of the screen width | 50 | From 0 to M*100, where M is the number of the installed monitors | |
The button | Click the button | Opens the window for changing the position and size of the SIP-panel window | NA | NA | NA | |
The Monitor drop-down list | Select the value from the list | Determines the number of the monitor in the system for which the coordinates are specified | Numbers of the monitors in OS | 1 | From 1 to 16 | |
The Operator interface settings group | ||||||
6 | The Terminal drop-down list | Select the value from the list | Sets the SIP-terminal object, which SIP-devices use the SIP-panel | Names of the SIP-panel objects registered in the system | NA | Depends on the number of the SIP-terminal objects in the system |
The Monitor drop-down list | Select the value from the list | Sets the Monitor object corresponding to the video surveillance monitor to which the cameras associated with the corresponding SIP devices are added | Names of the Monitor objects registered in the system | NA | Depends on the number of the Monitor objects in the system |
The Advanced settings tab
The table describes the parameters of the Advanced settings tab.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
The Interface behavior group | ||||||
1 | The Display only when calling checkbox | Set the checkbox | Displays the SIP-panel only when calling | Boolean type | Clear | Set—the SIP-panel is only displayed when calling Clear—the SIP-panel is always displayed |
The New calls to the end checkbox | Set the checkbox | Enables adding new calls to the end of the list | Boolean type | Clear | Set—new calls are added to the end of the list Clear—new calls are added to the top of the list | |
The Disable keypress sound checkbox | Set the checkbox | Disables keypress sound on the SIP-panel | Boolean type | Clear | Set—keypress sound disabled Clear—keypress sound is enabled | |
The Maximize screen on call checkbox | Set the checkbox | Enables automatic display switching on call | Boolean type | Clear | Set—when a call is made to the SIP-terminal that corresponds to the SIP-panel, the screen to which the SIP-panel is added is displayed automatically Clear—when a call is made to the SIP-terminal that corresponds to the SIP-panel, screens aren't switched automatically | |
The Calls to unknown users checkbox | Set the checkbox | Enables the option to call the unknown users. Note. Unknown user is a number that is present in the SIP-terminal but not in the address book of the current SIP-operator | Boolean type | Set | Set—calls to unknown users are allowed Clear—calls to unknown users are forbidden | |
The Switch to incoming checkbox | Set the checkbox | Automatically switches to the SIP-panel tab with the incoming calls, which occurs during incoming calls or calls on hold | Boolean type | Set | Set—automatic switch to the tab with incoming calls is enabled Clear—automatic switch to the tab with incoming calls is disabled | |
The Interface elements group | ||||||
2 | The Dial pad checkbox | Set the checkbox | Displays the dial pad in the interface | Boolean type | Set | Set—the dial pad is displayed Clear—the dial pad is hidden |
The Subject checkbox | Set the checkbox | Displays the tab names in the interface. When disabled, only the Call tab is displayed without displaying the name | Boolean type | Set | Set—the tab names are displayed Clear—only the Call tab is displayed without displaying the name | |
The Archive checkbox | Set the checkbox | Displays the Archive tab in the interface | Boolean type | Set | Set—the Archive tab is displayed Clear—the Archive tab is hidden | |
The Call control buttons checkbox | Set the checkbox | Displays the buttons at the bottom of the panel to control a call | Boolean type | Set | Set—call control buttons are displayed Clear—call control buttons are hidden |
The Operator settings tab
The table describes the parameters of the Operator settings tab.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
The Operators table | ||||||
1 | The Number drop-down list | Select the value from the list | Selects the SIP-operator identifier | Identifiers of the SIP-operator objects registered in the system | NA | Depends on the number of the SIP-operator objects in the system |
The Subscriber drop-down list | Select the value from the list | Selects the SIP-operator number | Numbers of the SIP-operator objects registered in the system | NA | Depends on the number of the SIP-operator objects in the system | |
The Name drop-down list | Select the value from the list | Selects the SIP-operator name in Axxon PSIM | Names of the SIP-operator objects registered in the system | NA | Depends on the number of the SIP-operator objects in the system | |
Out of the group | ||||||
2 | The Range button | Click the button | Opens the Add operators window to add multiple SIP-operators | NA | NA | NA |
3 | The All button | Click the button | Adds all existing SIP-operators to the table | NA | NA | NA |
4 | The Default drop-down list | Select the value from the list | Sets the default SIP-operator | NA | Select on start |
|
*Name of the element isn't displayed in the settings panel of the given object