Rule of change the indicator state allows to know how to change indicator of object on the map while coming value of parameter in the specified interval.

Configuring of this rule is performed on the Indicators tab on the settings panel of the FSG rule object. Description of parameters is presented in the following table. It is possible to specify not more than 10 states of indicator.

Parameter

Description of parameter

Rule #

Number of rule

Min value , Max value

Range of element values for rule

Min scale, Max scale

Range of values which indicator will take according to the rule

Use

Activation of interval

Red, Green, Blue

Set color of indicator by RGB model

Click the Apply button to save changes.

Indicator and its value are displayed in the map.