You can configure the BioSmart Quasar terminal on the settings panel of the BioSmart Quasar object created on the basis of the BioSmart object.
The Basic settings tab
- Go to the Basic settings tab.
- From the Working mode drop-down list, select the working mode of the terminal:
- Face identification—automatic identification of an employee by face.
- Entry/exit by button—the terminal waits for an employee to press the Enter or Exit button, after that it starts employee identification.
- Card + face—the terminal waits for the RFID card to be put to the terminal reader. If the card code is found, the terminal scans the biometric data of the employee's face and compares it with the biometric template corresponding to the presented card.
- RT identification—the terminal reads the biometric data of the face and sends it to the Rt Lab server for identification.
- Visitors check—the terminal waits for a visitor to present a QR code confirming the presence of a COVID certificate of vaccination or past medical history. After that, the terminal verifies the authenticity and validity period of the certificate. If the verification is successful, a message appears on the screen asking to wear a mask. Identification is considered successful only if a valid QR code is presented and the mask is put on the face.
- REST server mode—the terminal is a server that receives requests for identification.
- Entry/exit + room—the terminal waits for an employee to press the Entry, Exit or Room button, after that it starts employee identification. Operation of the terminal in the Entry/exit + room mode is similar to the operation in the Entry/exit by button mode, but an additional Room button is displayed on the screen. After pressing the Room button and successful identification, the employee is granted access to their profile, which contains information about the employee.
- From the Access direction drop-down list, select the Input, Output or Not assigned (default) value.
- From the Recognition algorithm drop-down list, select the recognition algorithm that will be used: BioSmart (default) or 3DiVi—image processing algorithm from the 3DiVi company.
- From the Severity level drop-down list, select the level of identification severity: Normal (default), Higher, High, Lower, Low. The parameter determines how accurately the biometric data of the user's face, received from the camera, must match the biometric template stored in the database.
- In the Relay open time, ms field, enter the time in milliseconds during which the terminal relay will be opened.
The Advanced settings tab
- Go to the Advanced settings tab.
- Set the Include passage through access sensor checkbox to take into account employee passages through door sensor.
- Set the Create templates from Access Manager photos checkbox, so that when a user is written to the Access Manager and if they have a photo, a biometric template is also created according to the selected algorithm (see step 3) and written to the BioSmart Quasar terminal.
- From the Template generation algorithm drop-down list, select an algorithm for creating a user biometric template: AUTO, ALGO2, or ALGO5. When you select ALGO2 or ALGO5, templates are created on Axxon PSIM side and are ready to be written to the terminal. If you select AUTO, a user photo is saved to the terminal and a template is created on the terminal side according to the algorithm configured in it.
The Wiegand 0 and Wiegand 1 tabs
- Go to the Wiegand 0 or Wiegand 1 tab.
- From the Direction drop-down list, select the direction of information transfer via the Wiegand interface:
- Wiegand Out—used to transfer information to external devices.
- Wiegand In—used to receive information from external devices.
- Not used—the Wiegand interface isn’t used to transfer information (default). If you select this value, further configuration isn’t relevant.
- From the Wiegand mode drop-down list, select the operation mode of the Wiegand interface: Wiegand 26, Wiegand 32, Wiegand 34, Wiegand 37, Wiegand 40, Wiegand 42, Wiegand 48, Wiegand 64.
- From the Data type drop-down list, select the type of the transferred data: Card ID—transfer of the RFID card code (default) or Employee ID—transfer of the employee code (ID).
- From the Pulse width, µs drop-down list and Sending interval, µs drop-down list, select the values of the data transfer parameters via the Wiagand interface. Default values: Pulse width, μs—200 μs, Sending interval, µs—2000 μs.
- Click the Apply button to save the changes.
Сonfiguring the BioSmart Quasar terminal is complete.