In ACFA Intellect software package the AC−215 controller object corresponds to Rosslare controller. This object is created on the basis of the Connection object on the Hardware tab of the System settings dialog box.
To configure AC−215 controller do the following:
- Go to the setting panel of the AC−215 controller object.
- From the Address dropdown list select the vacant controller address in the range from 1 to 32 (1).
- In the Period for re-connecting (min) field using up-down keys set the time (in minutes) during which the attempts to re-connect with AC−215 controller will be made (2).
- From the Panel type dropdown list select type of the panel in use (3).
- From the On the door dropdown list select the number of readers on one door (4).
- From the Time zone dropdown list select time zone in order to control the double pass (5).
From the Antipassback dropdown list select the control mode of double pass through the readers (6).
Pass mode
Description
Hard
If pass procedure is violated when the double pass is controlled then user access is forbidden and alarm is transmitted to the computer.
Soft
If pass procedure is violated when the double pass is controlled then user access is allowed and alarm is transmitted to the computer.
- In order to control the double pass set the checkboxes opposite corresponding readers (7).
- To save changes click Apply (8).
Configuration of Rosslare controller is completed.