Previous page Next page


The ZK C3-100, ZK C3-200, ZK C3-400 controllers are configured on the settings panel of the corresponding objects AC ZK Controller C3-100AC ZK Controller C3-200 and AC ZK Controller C3-400 which are created on the basis of the AC ZK Teco object on the Hardware tab of the System settings dialog window.

Note

The ZK Teco controller will be configured using the ZK C3-100 as an example. Other controllers are configured in the same way.

To configure the ZK Teco controllers, do the following:

  1. Go to the settings panel of the corresponding ZK Teco controller.
  2. From the Gate drop-down list (1), select the type of controller connection (see Configuring the connection via Ethernet standard or Configuring the connection via RS-485 standard).
  3. In the Password field (2), enter the password for controller connection.
  4. If the Ethernet connection type was selected, then enter the IP address of the controller in the IP field (3).
  5. If the the RS-485 standard connection type was selected, then select the connection COM port number from the Address drop-down list (3).
  6. From the Anti-passback drop-down list (4), select the mode of anti-passback operation:

    Mode

    Description

    Controller

    Disable

    The anti-passback function is disabledAll controllers
    Readers of Door 1The anti-passback function is enabled between the readers of Door 1ZK C3-100, ZK C3-200
    Readers of Door 2The anti-passback function is enabled between the readers of Door 2ZK C3-200
    Readers of door 1, readers of door 2The anti-passback function is enabled between the readers of Door 1 and Door 2 respectivelyZK C3-200
    Door 1 and 2The anti-passback function is enabled between the readers of Door 1 and Door 2ZK C3-200, ZK C3-400
    Doors 3 and 4The anti-passback function is enabled between the readers of Door 3 and Door 4ZK C3-400
    Doors 1 and 2, doors 3 and 4The anti-passback function is enabled between the readers of Door 1, Door 2, Door 3 and Door 4ZK C3-400

    Doors 1, 2 and doors 3, 4

    The anti-passback is enabled between Door 1, 2 and Door 3, 4ZK C3-400
    Door 1 and doors 2, 3The anti-passback is enabled between Door 1 and Door 2, 3ZK C3-400
    Door 1 and doors 2, 3, 4 The anti-passback is enabled between Door 1 and Door 2, 3, 4ZK C3-400
  7. From the Interlock drop-down list (5), select the mode of doors interlocking:

    Mode

    Description

    Controller

    Disable

    The interlock function is disabledAll controllers
    Door 1 and 2Doors 1 and 2 are interlocked mutuallyZK C3-200, ZK C3-400
    Door 3 and 4Door 3 and door 4 are interlocked mutuallyZK C3-400
    Doors 1, 2 and 4Door 1, door 2 and door 4 are interlocked mutuallyZK C3-400

    Doors 1 and 2, doors 3 and 4

    Door 1 and door 2 are interlocked mutually, door 3 and door 4 are interlocked mutuallyZK C3-400
    Doors 1, 2, 3 and 4Door 1, door 2, door 3 and door 4 are interlocked mutuallyZK C3-400

    Note

    To open one of the interconnected doors, the other interconnected doors in the group must remain closed. This means that in a group of interconnected doors, only one door can be opened at a time.

  8. From the Backup period drop-down list (6), select the time interval in minutes for the automatic backup of data of the specified type (see Managing the configuration of a ZK controller). 
  9. Set the Watch dog checkbox (7) to enable the automatic data backup.

  10. Click the Apply button (9).

    Note.

    After a successful connection with the controller is established, the firmware version and the controller serial number will automatically be displayed in area (8).

Configuring the ZK C3-100, ZK C3-200, ZK C3-400 controllers is now completed.