To configure discrete and alarm inputs of controller, do the following:
- Click the Entry parameters on the settings panel of the BioSmart PROX object.
- Set the following parameters for each discrete input:
- In the Active level list select the level of signal at discrete input at which the access sensor triggering is detected (1).
- In the corresponding list select the relay of controller that is event-triggered on the discrete input (2).
In the Eventlist select the type of event processed by controller when the signal of specified level arrives to discrete input (3).
Types of event processed by controller are presented in the following table.Event type
Description
Not assigned
Signals from corresponding discrete input are not processed
Relay control button
Signal of specified level caused by pushing the button is processed
Access sensor
Signal of specified level caused by walking through the turnstile or the door is processed
Unlocking sensor
Signal of specified level caused by unlocking the relay is processed
- In the Timer field specify time (in milliseconds) of active state of the relay after its triggering (4).
- In the Active level list select the level of signal at discrete input at which the access sensor triggering is detected (1).
- Specify the following parameters for each alarm input:
- In the Active level list select the level of signal occurring at alarm input – it triggers access sensor (5).
- In the Event list select the type of sensor which triggering causes controller action (door locking, door unlocking, fire alarm activation, 6).
- Click the OK and then the Apply button.
Discrete and alarm inputs of controller are now configured.