BioSmart Prox v.2 and BioSmart Prox-E controllers support 3 operation modes.
Note.
The Escort operation mode is currently not supported by ACFA Intellect.
Operation modes of BioSmart PROX v.2 and BioSmart PROX-E controllers are presented in the following table.
Operation mode | Description |
Standard | Access is guaranteed when scanning a fingerprint or access card |
Multi-access | Access is guaranteed when scanning fingerprints (placing access card) on different sides of the door |
Gateway | Access is guaranteed to the walk-through premises, the second door can't be opened before the first door is closed |
Operation mode is configured as follows:
- Select the controller's operation mode in the Access mode dropdown list (1).
- If the Multi-access mode is selected, then in the Waiting time field specify maximum possible time (in milliseconds) between scanning fingerprints (placing access cards) on different sides of the door (2). If this time-limit is exceeded, then access is denied.
- If the Gateway mode is selected, then match sensors and access points with discrete inputs (3).
- Click the Apply button to save all changes.
Operation mode is now configured.