Unable to render embedded object: File (books.jpg) not found.
Go to documentation repository
Documentation for Auto Intellect 5.4. Documentation for other versions of Intellect is available too.
Previous page Next page
The Uragan Module module object settings panel contains the following interface elements:
The following table describes the elements of the Uragan Module object settings panel.
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
---|---|---|---|---|---|---|
1 | Sensitivity of vehicle detection (1-255) field | Setting the value in the field | Set detector sensitivity to picture contrast of the car | Lux | 25 | 1-255 |
2 | Car position in frame, % field | Setting the value in the field | Set car position in frame between the moments of car appearance and disappearance from the frame | % regarding the frame | 15 | 0-100 |
3 | Full interval between cars checkbox | Setting check box | Switch recognizer to waiting mode of motion absence all over the frame | Boolean type | No | Yes – recognizer is in waiting mode of motion absence all over the frame. |
4 | Recognize license plates only in areas where motion is detected checkbox | Setting check box | Switch recognizer into the mode in which the plate recognizing is performed only in areas where motions was detected. | Boolean type | No | Yes – recognizer works with those areas where the motion was detected. |
5 | Minimun validity of LP recognition (60-100%) field | Setting the value in the field | Set the minimal allowed validity of LP recognition | Integer non-negative number | 85 | 60-100 |
6 | Obscured LPs checkbox | Setting check box | Enable the possibility of obscured LP recognition | Boolean type | No | Yes – recognition of cars with obscured plates is enabled. |
7 | Number of lanes in camera field of view | Non-edited field | Displays the number of lanes in camera field of view | Integer non-negative number | - | - |
8 | Allow | Setting chech box | Enable the possibility of two-lines license plates recognizing | Boolean type | No | Yes – two-lines LPs are recognized. |
9 | Maximal width | Setting the value in the field | Maximal width of the two-lines license plates | % regarding the frame | - | Unlimited |
Maximal height | Setting the value in the field | Maximal height of the two-lines license plates | % regarding the frame | - | Unlimited | |
Button X | Click the button | Access to the interactive interface of setting the area width and height of two-lines license plates | - | - | - | |
10 | Minimall width | Setting the value in the field | Minimal width of the two-lines license plates | % regarding the frame | - | Unlimited |
Minimal height | Setting the value in the field | Minimal height of the two-lines license plates | % regarding the frame | - | Unlimited | |
Button X | Click the button | Access to the interactive interface of setting the area width and height of two-lines license plates | - | - | - | |
11 | Typical minimum size | Non-edited field | Displays the typical minimum size of license plate | Integer non-negative number | - | - |
Typical maximum size | Non-edited field | Displays the typical maximum size of license plate | Integer non-negative number | - | - |