The Vehicle tracer settings panel contains the following interface elements:
- The Basic tab
- The Monitor tab
- The Alarm window tab
The following table describes the elements of the Vehicle Tracer object settings panel.
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range | |
---|---|---|---|---|---|---|---|
1 | ID number | Automatically | Displays the Vehicle tracer object's ID number in the system | Number | - | From 1 and above. | |
2 | Name | Enter the value in the field | Set the Vehicle tracer object name in the system | Latin, Cyrillic and special symbols | The Vehicle tracer | A sting, containing a sequence of characters (letters, digits, characters)non case-sensitive | |
3 | Disable | Is set with a checkbox | Set the Vehicle tracer object's state (enabled or disabled) in the system | Boolean type | No | Yes –The Vehicle tracer object is disabled and not in use | |
4 | Screen | Select from the list | Set the screen parent object in the system, to which this Vehicle tracer object is related | Names of Screen objects, registered in the system | Name of the Screen parent object | Depends on the number of Screen objects | |
5 | Basic | Go to the tab | Access to settings of the component position Active monitor on the screen | - | - | - | |
6 | Show | Is set with a checkbox | Displays the Active monitor component on the screen | Boolean type | No | Yes – Active monitor components is displayed on the screen | |
Coordinates group on the Basic tab | |||||||
7 | Field X | Enter the value in the field | Set the horizontal coordinate of the X axis of the Active monitor's component left upper corner on the screen | % regarding the screen's width | - | From 0 to М*100, where М – is the number of installed video surveilance monitors | |
Field Y | Enter the value in the field | Set the vertical coordinate of the Y axis of the Active monitor's component left upper corner on the screen | % regarding the screen's height | From 0 to М*100, where М – is the number of installed video surveilance monitors | |||
Field W | Enter the value in the field | Set the width of the Active monitor's component | % regarding the screen's width | - | From70 to М*100, where М – is the number of installed video surveilance monitors | ||
Field H | Enter the value in the field | Set the height of the Active monitor's component | % regarding the screen's height | - | From 39 to М*100, where М – is the number of installed video surveilance monitors | ||
Button X | Click the button | Entering the text window for visual setiing the coordinates and sizes of the Active monitor's component | - | - | - | ||
Allow moving | Is set with a checkbox | Enables moving the Active monitor's component | Boolean type | No | Yes – moving is permitted | ||
Plates recognizers group | |||||||
8 | Available | Automatically | Displays the list of LP recognisers servers, available for displaying in the Vehicle tracer interface window | - | - | - | |
Selected | Automatically | Displays the list of LP recognisers servers,displayed in the Vehicle tracer interface window | - | - | - | ||
Buttons >, <, >>, << | Click the button | Selection of LP recognisers servers, to be displayed in the Vehicle tracer interface window | - | - | - | ||
External databases group | |||||||
9 | Available | Automatically | Displays the list of External Platesd databases, that may be used for the identified objects analysis | - | - | - | |
Selected | Automatically | Displays the list of External Platesd databases, selected for the identified objects analysis | - | - | - | ||
Buttons >, <, >>, << | Click the button | Selection of Platesd databases for the identified objects analysis | - | - | - | ||
10 | Settings | Click the button | Access to The Vehicle tracer interface and also to the voice notification settingswhile registering the alarms: overspeeding, identification of the plate in the external database | - | - | - | |
11 | Control monitor | Select from the list | Set the Monitor interface object to play back the video archive from the LP recognition camera upon the command from the Vehicle tracer window | Names of Monitor objects, registered in the system | - | Depends on the number of Monitor objects, registered in the system | |
12 | Monitor | Go to the tab | Access to the settings of Events monitor component on the screen | - | - | - | |
13 | Show | Is set with a checkbox | Displays the Events monitor component on the screen | Boolean type | No | Yes – the Events monitor component is displayed on the screen | |
Coordinates group on the Monitor tab | |||||||
14 15 16 | Field X | Enter the value in the field | Set the horizontal coordinate of the X axis of the Events monitor's component left upper corner on the screen | % regarding the screen's width | - | From 0 to М*100, where М – is the number of installed video surveilance monitors | |
Field Y | Enter the value in the field | Set the vertical coordinate of the Y axis of the Events monitor's component left upper corner on the screen | % regarding the screen's height | - | From 0 to М*100, where М – is the number of installed video surveilance monitors | ||
Field W | Enter the value in the field | Set the width of the Events monitor's component | % regarding the screen's width | - | From 0 to М*100, where М – is the number of installed video surveilance monitors | ||
Field H | Enter the value in the field | Set the height of the Active monitor's component | % regarding the screen's height | - | From 0 to М*100, where М – is the number of installed video surveilance monitors | ||
Button X | Click the button | Entering the text window for visual setiing the coordinates and sizes of the Events monitor's component | - | - | - | ||
Allow moving | Is set with a checkbox | Set the possibility of moving the Events monitor's component | Boolean type | No | Yes – moving is permitted | ||
Alarm window | Go to the tab | Access to the settings of Alarm window component on the screen | - | - | - | ||
Show | Is set with a checkbox | Displays the Alarm window component on the screen | Boolean type | No | Yes – the Alarm window component is displayed on the screen | ||
Coordinates group on the Alarm window tab | |||||||
17 | Field X | Enter the value in the field | Set the horizontal coordinate of the X axis of the Alarm window's component left upper corner on the screen | % regarding the screen's width | - | From 0 to М*100, where М – is the number of installed video surveilance monitors | |
Field Y | Enter the value in the field | Set the vertical coordinate of the Y axis of the Alarm window's component left upper corner on the screen | % regarding the screen's height | - | From 0 to М*100, where М – is the number of installed video surveilance monitors | ||
Field W | Enter the value in the field | Set the width of the Alarm window's component | % regarding the screen's width | - | From 0 to М*100, where М – is the number of installed video surveilance monitors | ||
Field H | Enter the value in the field | Set the height of the Alarm window's component | % regarding the screen's height | - | From 0 to М*100, where М – is the number of installed video surveilance monitors |