Documentation for Face Intellect 7.3. Documentation for other versions of Intellect is available too.
Previous page Next page
The Cfgedit.exe utility allows configuring the Cognitec face recognizer.
To configure the Cognitec face recognizer the following parameters are in use: MinEyeDistance, MaxEyeDistance and FieldOfViewAngle. To find them open the objects tree as it shown in the figure.
The MinEyeDistance parameter (1) defines the minimal distance between eyes which is to be recognized. The range of values is [0.000-1.000]. The value on default is 0.1. The distance is measured in fractions of video image width.
The MaxEyeDistance parameter (2) defines the maximal distance between eyes which is to be recognized. The range of values is [0.000-1.000]. The value on default is 0.4. The distance is measured in fractions of video image width.
The FieldOfViewAngle parameter (3) defines the camera view angle. The range of values is [0.1-179.9]. The value on default is 60. This parameter is measured in degrees.
To change the value of corresponding parameter double click the left mouse button on it. The Change item window will open.
In the field (1) enter the required value for corresponding parameter. To save the entered value, click Ok (2). To set the default value, click Reset to Default button (4).
Note.
To cancel the entered value click the Cancel button (3).
To reset all settings to default select the Edit - > Deep Reset To Default menu item. Parameter values will change to default values only after closing and opening the object tree.
Configuration of the Cfgedit.exe utility wll be applied after the Intellect software restart. Stopping the utility is not required.