Configure the special operation mode on the Server Of Control side as follows:

  1. Create and configure the Server Of Control object on the Hardware tab (see Configuring Server of Control).
  2. Create and configure one or several External Plates DB objects on the Hardware tab (see Connecting and setting up of the external LP number database).
  3. Create and configure the Monitoring object on the Interfaces tab (see Configuring the Monitoring interface object).
  4. Create the ULPR section in the Windows registry if it is not created yet (see Registry keys reference guide. For more details on how to operate the registry, see Working with Windows OS registry).
  5. In the ULPR section of the Windows registry, create the ULPRspecialProcessing string parameter and set its value to 1 (see Registry keys reference guide. For more details on how to operate the registry, see Working with Windows OS registry).
  6. Restart the computer to apply the changes.

As a result, the Info on vehicle license plates button becomes available in the Log panel and Details window of the Monitoring interface. The License plate search window opens when you click this button (see Viewing recognized LPs).

Note

By default, the LP found in the database alarm is generated for the Entrance recognition point only. In order to generate alarm both on Entrance and Exit points, in the ULPR section of the Windows registry, create the AlarmMsgOne string parameter and set its value to 0 (see Registry keys reference guide. For more details on how to operate the registry, see Working with Windows OS registry).

Configuring the special operation mode on the Server Of Control side is now completed.