Documentation for Axxon Next 3.5.1. Documentation for other versions of Axxon Next is [available too].

To configure VMD, you must perform the following steps:

  1. In the Detection Tools list, highlight a Motion object (1).
  2. In the Sensitivity field: contrast (2) , enter the sensitivity of the detection tool to object contrast. You should select a value empirically in the range [0, 16]. The greater the value, the less contrastive the objects which can be detected.
  3. In the Sensitivity field: size (2), enter the sensitivity of the detection tool to object size. You should select a value empirically in the range [0, 10]. The greater the value, the smaller the objects which can be detected.
  4. In the viewing tile, set detection zones and/or masks in the same way as for situation analysis detection tools (3).

    Note

    See steps 2–4 in the section Setting Common Detection Zones

  5. Click the Apply button.

VMD configuration is now complete.