Documentation for Axxon One 1.0.

Previous page Next page

To detect a sitting pose, you have to configure scene perspective first.

Please follow the steps below:

  1. Select a detection tool, and click  in the preview window.
  2. Set the size of the same human figure in different areas of FOV. To create a leveling rod, left-click on the video image to add two anchor points. You should set no less than three leveling rods. The leveling rod height must correspond to a human figure placed in the same point of the scene. You can resize the rod by stretching its anchor points , or move it on screen by dragging and dropping.

    Attention!

    When setting up leveling rods, please make sure that the following conditions are met:

    1. All rods have different height.
    2. All rods must be based on the same plane (for example, floor).
    3. In complex scenes where detection accuracy is crucial, we recommend you to add more than 3 rods.
    4. In areas where the picture is apparently distorted, place the rods in parallel to known vertical elements (doors, bookcases, etc.).

    Attention!

    In portrait-oriented scenes (such as store/warehouse aisles, etc.), set the rods in triangles.

    Note

    For your convenience,  you can click the button to freeze the video. To unfreeze, click the button once more.

    Note

    To delete a rod, click the  button.

  3. Click Apply button.
  • No labels