Documentation for POS Intellect 5.4. Documentation for other versions of Intellect is available too.

Previous page General information about POS Process system object  Clearing the counter Next page

The POS Process system object is created under the Computer object in the Hardware tab of the System setting dialog box.  

 


To configure the POS Process system object do the following:

  1. Go to the settings panel of the POS Process object.
  2. POS terminal objects created in the object tree are listed in the Available POS terminals list (1).
  3. Move required terminals to the Selected POS terminals using  and  buttons (2). Information from selected terminals will be in use to count cases of appearing the specified parameter.

    Note.

     To back POS terminals from the Selected POS terminals list to the Available POS terminals list use  and  buttons.
  4. In the Parameter name field enter the name of parameter at which the number of equal values is to be controlled (3). Parameter name is depends on protocol characteristics on which the terminal works.
  5. In the Maximal number field enter the maximal number of appearance of equal parameter values (4).
  6. In the Additional information enter the events description which will be included to the event description next to the card number and number of repeats (5).
     

    Note.

    In example displayed in the figure, the description of alarm messages will be presented as «Some information 3x123», where 123 is a card number, 3 is a number of times when the parameter appeared.
  7. From the Clear counter by time zone activation drop-down list select the Time zone object corresponding to the time period start of which shows the necessity to reset the counter of parameter appearances (6).
     

    Note.

    The Time zone objects are created and configured on the Programming tab of System setting dialog box. Detail information about creating and configuring the time zone is presented in the Intellect software package. Administrator’s Guide document.
  8. Click the Apply button (7).

Configuration of the POS Process system object is completed.