Documentation for POS Intellect 5.4. Documentation for other versions of Intellect is available too.

Previous page Next page

In case the POS-server abnormally disconnects from the MixForward utility, is can be re-connected.

To restore the correct connection, make sure the POS-terminal object is set up in the following way (see the Selecting the type of POS-terminal and setting the connection parameters section):

  1. XML-data receipt via TCP protocol is expected;
  2. The Keep connection checkbox is set checked.

If the Keep connection option is enabled, the POS-server registers the connection of the utility and determines the time interval since the last data transfer. If the data has not been received for more than 30 seconds, the POS-server breaks the connection and re-establishes it again.

Note

If no data has been received from POS-terminals, the utility sends the control packages containing the FunctionNumber 77777 element to the POS-server at 5 second intervals.

Important!

If there is connection loss or errors when sending data from MixForward utility in POS-Intellect, then the Keep connection checkbox is to be set unchecked.

To close the MixForward utility and stop the data package routing process, select Close in the File menu.

Note

Clicking the  button in the upper right corner of the window closes the window, but does not stop the routing process.
  • No labels