Documentation for POS Intellect 5.4. Documentation for other versions of Intellect is available too.
The ReaderSrv utility settings are stored in the ReaderSrv.ini utility configuration file which is located in the <POS-Intellect installation directory>\Modules\Pos\Scanners\Metrologic MS9500 Voyager folder.
- The Ip and port parameters are mandatory and are necessary for the utility to transfer data over the network to the specified ip-address and port number.
- The Period parameter sets the time in milliseconds after which the specified characters will be automatically transferred.
Note
If the 0 value is set, then the specified characters will be transferred only by pressing the Enter key.
- The debug parameter is optional. If it is not set, its value is automatically set to 0. If the debug parameter is zero, the utility window is not displayed.
To start ReaderSrv, run the ReaderSrv.exe file. The utility is launched in hidden mode. To display the Reader Server window double click
icon in the Windows notification area.The Reader Server window is divided into the following parts:
- In the upper left section of the window error messages and other information on program functioning will be displayed. The debug parameter value must not be less than 1.
- In the upper right section of the window the XML formed for sending is displayed. The debug parameter value must not be less than 2.
- In the bottom right section of the window the readed bar codes and all information received from the keyboard or other reader, simulating the keyboard, are displayed. The debug parameter value must not be less than 3.
To hide the window, click
in its upper right corner. To display the window again, double click icon in the Windows notification area (system tray).Overview