Documentation for Monitoring 12.0. Documentation for other versions of Monitoring is available too.

Previous page Configuring sound notification at Server of Control  Configuring sound notification at Server of Control for various alarm groups Next page

The Monitoring software allows configuring audio feedback for alarms received from an Agent of Control. For this do the following:

Note.

This function is not supported for the Additional Workplace in non-distributed configuration.
  1. Create a Display object in the Interfaces tab.
  2. Create an Audio player object on the base of the Display object.
  3. Run the System configuration utility (ddi.exe).

    Note.

    Detailed info on using this utility is given in the Intellect software. Administrator's Guide. The most relevant version of this document is available in AxxonSoft documentation repository.
  4. Open the intellect.atm.ddi file.
  5. Select the VIDEOSRV_S_DVC (Partition of control) object.
  6. Go to the Events tab.
  7. In the Audio support column set checkboxes for all events that have to be followed by an audio signal.
    A screentip shows the required name of the wav file.
    N is an ID of the VIDEOSRV_S_DVC_ATM object.
  8. Create corresponding files and put them to the <Intellect installation>\Wav folder.

Configuration of sound notification at Server of Control is completed.

  • No labels