Documentation for Monitoring 14.0. Documentation for other versions of Monitoring is available too.

Previous page Status bar  Object status Next page

The number of objects displayed on the Log Panel or Control panel is determined by the current filter if it is enabled with the filtering button (Turn filter on/off).

The left list displays only the objects with alarms or failures, the connected or disconnected objects only. The middle list displays time periods. If there was an alarm during the selected period, it is included on the list. The right list displays the alarm durations that trigger the filter. For example, if you set the filter to "Current"-"1 minute", only those objects are displayed that are currently in the alarm state and that have already been in this state for one minute or more. If you set the filter to "Day"-"5 hours", only those objects are displayed that have at least once been in the alarm state in the last 24 hours and that were in this state for at least five hours.

To calculate the rates (IF% and IN%) and camera statistics (Cam) only for the filtered objects, click the button (Calculate rates and cameras only for filtered table lines). If the Alarms, Failures or Disconnected filter is enabled, rates are not calculated.