  1. Go to Traffic violations detection setting tab.
  2. In Traffic lights signal dropdown list select Sensor object (see Intellect software package: Administator's Installing and configuring security system components guide) by signal of which the light of traffic light is detected (1).

    Info
    titleNote.

    Information about Sensor object is presented in the Intellect Software Package. Administrator's Guide. software package: Installing and configuring security system components guide. Information about Traffic Light Detection is presented in The Traffic Light Detection software module setup section.

    Note
    titleAttention!

    For correct operation of the Traffic violations detection module disarm the corresponding Sensor object.

  3. Set the Draw stop line checkbox if it's necessary to overlay a stop line before the traffic light (2).
  4. Set up the stop line displaying:
    4.1 Click Stop line settings (3). The window of the same name opens.

    4.2 Click Stop video to set the stop line. As the result the frame on which it's necessary to set the stop line, is displayed.

    4.3 Set the stop line. To set the stop line, click the road edge in the image, press the left mouse button, drag the cursor to another edge of the road in the video frame.
    4.4 Click OK.
  5. In the Delay in violation registering field enter time (in milliseconds) that determines the time interval after which after switching on a red light the violations will fix (4).
  6. Enter the number of frames that will be saved in database in the The number of frames to save field at the running a red light (5). Only 10 frames are saved in database in case of value more than 10 is specified.
  7. Enter time (in milliseconds) that determines the time interval of frames for saving in the Frame saving interval field at the running a red light (6).
  8. From the Type of violation drop-down list select the type of traffic violation that will be specified in the caption to the alarm while the Stop violation is registered (7).

    Info
    titleNote.

    The following violation types are available: Stop over stop line and Stop over crosswalk line.

  9. Enter the number of frames that will be saved in database in the The number of frames to save field when the Stop violation is registered (8).
  10. Enter time (in milliseconds) that determines the time interval of frames for saving in the Frame saving interval field when the Stop violation is registered (9).

    Note
    titleAttention!

    For correct operation of synchronized frames recording set the checkbox in Automatic recording on LPR channel object setting panel and set value of time that is bigger than the product of Number of frames for saving and Interval of frame saving parameter points.