The KeyKing connection line is configured in the ACFA Intellect Software System on the KeyKing Connection Line object's settings pane. This object is created based on a KeyKing ACS object on the Hardware tab of the System Settings dialog (Fig. 2.3—1).

Image Added

Anchor_Ref330221056_Ref330221056Fig. 2.3—1 KeyKing Connection Line object
To configure a KeyKing connection line, do the following:

...

  1. Go to the KeyKing Connection Line object's settings pane (Fig. 2.3—2).

...


  1. Image Added

...

  1. Use the up/down buttons to enter the COM-port polling interval in seconds in the Delay, ms field (see Fig. 2.3—2, 1).
  2. Select the connection method for the KeyKing connection line from the Line type dropdown list: COM port, TCP server, or TCP client (see Fig. 2.3—2, 2).
  3. If COM port is selected, use the up/down buttons to enter the KeyKing connection line's port number in the Port field (see Fig. 2.3—2, 3).
  4. If either TCP server or TCP client is selected, then do the following:
    1. Specify the connection line's IP address using the IP address field (Fig. 2.3—3, 1).

...

    1. Image Added
    1. Use the up/down buttons to enter the connection line's TCP-connection port in the Port field (see Fig. 2.3—3, 2).
    Info
    titleNote

...

  1. .

    A controller connected as a TCP server uses the connection line to listen for messages from devices. A controller connected as a TCP client uses the connection line to send messages about its presence

...

  1. Click the Apply button.

This completes the configuration of the KeyKing connection line.