Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Traffic violations detection module object settings panel contains the following interface elements:

Image Modified

The following table describes the elements of the Traffic violations detection object settings panel.
 

The number of frames to save the number of frames to save in the database while the running a red lightThe number of frames to save frames to save in the database when the Stop violation is registeredFrame saving interval frame saving interval when the Stop violation is registered5000-20000

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

Traffic lights signal dropdown list

Selecting the value in the list

Selecting «Sensor/Detector» object, by signal of which traffic light is detected

List of accessible «Sensor/Detector» objects

no

Depending on number of accessible «Sensor/Detector» objects

2

Draw a stop line checkbox

Setting check box

Draw a stop line on video in front of traffic light function activation

Boolean type

no

Yes – drawing a stop line function is active
No – drawing a stop line function is off

3

Stop line settings button

Clicking

Access to stop line settings

-

-

-

4

Setting violation areas button

Clicking

Access to stop line settings

-

-

-

5

Delay in violation registering field

Setting the value in the field

Set period after which the running a red light or stop will be considered as a violation

Millisecond

1000

0-200005

6Time of stop for recording fieldSetting the value in the fieldSet

Whole nonnegative number

2

From 1 to infinity

6

Frame saving interval field

Setting the value in the field

Set frame saving interval while the running a red light

Millisecond

500

0-20000

7

Type of violation drop-down list

Selecting the value in the list

Selecting the type of traffic violation that will be specified in the capture to the alarm when the Stop violation is registered

List of available violation types while the stopping – Stop over stop line or Stop over crosswalk line

Stop over stop line

-

period that determines the time interval during which the vehicle should stay still while registering the Stop over crosswalk line violationMillisecond3000 
7Number of add.photos:

8

fieldSetting the value in the fieldSet the number of photos made before the licence plate fixing and after its going out the control zoneWhole nonnegative number2From 1 to infinity

9

8Interval: fieldSetting the value in the fieldSet period that determines the time interval between saving additional photosMillisecond1000