  1. In the System settings window, go to the Hardware tab (1).
  2. Create an IIDK interface object based on a Computer object (2). The Set the ID of the IIDK interface object should be larger than 100 (3).
  3. Create an Agent of Control object based on a Computer object.
  4. After an Agent of Control object is created in the right part of the System settings window, a panel appears for configuring the object.
  5. In the IIDK Interface No. field, enter the object ID for the IIDK interface created in step 2.
  6. Create one or more child Partition Of Control objects based on the Agent of Control object.
  7. After the Partition Of Control object is created in the right part of the System settings window, a panel appears for configuring the object.

...