Data loading from database to the interface objects
Information The information on Control panel and Log panel is updated every time data is loaded from the database. The time of the last download from the database is shown in the CDT CVT field.
Periods of data updating are different for Control panel and Log panel:
...
The date of last load of data to the database (see section Alarm list navigation) is refreshed when changes in the database appear.
If there is was no any change in the database in for 5 minutes, the CDT CVT field is forcibly updated updated and then is updated updates once a minute. At the same time there will be This will cause a gap from the current system time by 5 minutes. After coming of new information from any of the ATM-Intellect Pro, the CDT become CVT becomes equal to the current system time of the computer.
Loading data to the database database is performed by the Data loader for Monitoring module.
If files with technical information are received from Agents of Control ATM-Intellect Pro (e.g. camera enabled), these files are loaded to the database with a period specified while configuring Data loader in the Loading period parameter (10 seconds by default). If files with information on alarms are received from Agents of Control from ATM-Intellect Pro (e.g. vibration sensor triggered), this information is loaded to the database immediately.
...
ATM-Intellect Pro sends to ATM-Intellect Workstation packages with its technical condition with a period set while setting up the Partition of Control object at the ATM-Intellect Pro side using the Ping frequency parameter (see ATM-Intellect. Administrator's Guide, section Configuring connection between ATM-Intellect Pro and ATM-Intellect Workstation). The default ping ping frequency is 2 minutes (120 seconds).
Information on long-term alarms comes to the ATM-Intellect Workstation from ATM-Intellect Pro together with the information on technical condition , with once in the ping period.
Information about short-term alarms comes to the ATM-Intellect Workstation immediately after they have appeared at the ATM-Intellect Pro.
...
If necessary, ATM-Intellect Workstation can retranslate technical condition data to the ATM-Intellect Workstation TC. Alarms are not transmitted to the ATM-Intellect Workstation TC for it is presumed to be installed in facilities of a third party service company which should have access to the information on equipment failures but not to the information on alarms.
After the data data have been received by Data loader for monitoring at the ATM-Intellect Workstation TC, they are processed similar to the way they are on the ATM-Intellect Workstation – recorded to the database with the loading period and then, by request or by timer, are displayed in the interfaces.
...
- If a long-term alarm had started and ended within two polls of ATM-Intellect Pro (within the Ping frequency interval, see ATM-Intellect. Administrator's Guide).
- If a long-term alarm had started and ended when the connection between ATM-Intellect Pro and ATM-Intellect Workstation was lost.
...
- Information on disk failures (the Disk failure alarm type) and its re storing is updated at ATM-Intellect Pro startup and then every 15 minutes.
- Information on archive size (the Archive the Archive size too small alarm type) is updated at ATM-Intellect Pro startup and then every 15 minutes.
- Information on the computer normal and abnormal restarts is displayed in the interface in 5 minutes.
- Information on free disk space is updated every 1 hour.
- ATM-Intellect Pro initiates the connection with ATM-Intellect Workstation and once in a ping period (2 minutes by default) sends a package with technical data to the ATM-Intellect Workstation. If ATM-Intellect Workstation haven’t have not been receiving any data from ATM-Intellect Pro within 6 minutes, the “No connection” error is displayed for such object.
- The Video.run process status (hangup) is checked at startup of Videosrv.exe module and then every 15 minutes, and besides that each time the Videosrv.exe module reconnects with the Intellect software, i.e. if the Intellect software was shut down and started again.
- Availability of running processes "Intellect.exe" and "Video.run" is checked every 10 seconds.